Installation Considerations 
Proper location of detection devices is one of the most 
critical factors in a fire alarm system.  
Here are some general considerations: 
 
Do not install smoke detectors in “dead air” spaces 
or close to ventilating or air-conditioning outlets 
because smoke might be circulated away from the 
detector. Locations near air inlets are favored.   
 
Avoid areas subject to normal smoke 
concentrations such as kitchens, garages, or near 
fireplaces. 
 
Do not install smoke detectors where normal area 
temperatures are above 38 °C (100 °F) or below 0 
°C (32 °F).  
 
Avoid areas of high humidity and dust 
concentrations.  
 
Install ceiling-mounted detectors so the edge is no 
closer than 10 cm (4 inches) from any wall. 
 
Place the top edge of wall mounted detectors from 
10 to 30 cm (4 to 12 inches) from the ceiling. 
 
Figure 4:  Smoke Detector Installation 
 
 
1 – Rec Room 
2 – Dining Room 
3 – Kitchen 
4 – Bedroom 
5 – Living Room 
*
 – Smoke Detector 
Install smoke detectors between sleeping areas and 
family living areas. 
 
7.9 
Emergency Keypad Alarms/ 
Silencing Alarms 
The Emergency Alarm Keys [
], [
], and [
] can 
generate Fire, Special Emergency, and Panic Alarms if 
programmed by the installer. Ask your installing 
company to explain the function of these keys. 
To use 
an Emergency Key, you must press the button for 
two seconds to generate an alarm. Use the 
Disarming Command Sequence to cancel or silence 
these alarms. 
If the Emergency Alarm Keys are to be used, label the 
keys to signify their functions.   
Label the left-most key as the Fire key. This is the only 
key that can be designated as the Fire key. 
Label the middle key as the Special Emergency key. 
Label the right-most key as the Panic key.  
On RF keyfobs, the Panic signal is sent to your security 
system when two keys are held down simultaneously 
for at least three seconds.  
 
Figure 5:  Emergency Keypad Alarms 
 
1
2
3
4
5
6
7
8
9
0
*
#
1
2
3
4 5
6
7
8
9 10 11 12 13 14 15 16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenced
Trouble
System
Reset
Bypass
No
Entry
Perimeter
Only
Off
On
Armed
Status
Power
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
 
1 – Emergency Keys