Bosch Appliances Video Game Controller D9412GV2 用户手册

下载
页码 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 68 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
L## Master Arm Delay 
L## Perim Delay 
Default: 
Refer to the program record sheet 
Default: 
Refer to the program record sheet 
Selection
Blank or E 
Selection: 
Blank or E 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
[COMMAND][3] 
Perimeter Delay 
Arm 
[COMMAND][1] 
Master Arm 
Delay 
Delay arm all Perimeter Delay point responses only in 
the area where the keypad is assigned. 
Master arms areas based on the CC# Scope of the 
keypad using an exit delay time. 
L## Watch Mode 
When this item is accessed through the Function List, 
Master Arm All allows the user to arm all areas 
according to the authority level of the user and within 
the CC# Scope of the keypad using an exit delay 
time. 
Default: 
Refer to the program record sheet 
Selection: 
Blank or E 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
Arm Area arms only the area displayed. If COMMAND 
1 is used, it arms only the area where the keypad is 
assigned. 
6 Watch 
Mode 
[COMMAND][6] 
Initiate the Watch Mode in the area to which this 
keypad is assigned. 
L## Mstr Arm Inst
 
L## Perim Partial 
Default: 
Refer to the program record sheet 
Selection: 
Blank or E 
Default: 
Refer to the program record sheet 
Selection: 
Blank or E 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
[COMMAND][1][1] 
Master Arm 
Instant 
[COMMAND][8] 
Perimeter Partial 
Arm 
This authority level permission allows a user to 
execute the Master Arm Inst function. Refer to Mstr 
Arm Inst
Partially arms only the area where the keypad is 
assigned. 
 on page61
Arm Area arms only the area to which the keypad is 
assigned. 
If COMMAND 11 is used, it arms only the area where 
the keypad is assigned. 
 
 
Use COMMAND 11 carefully because all 
Perimeter and Interior points become 
Instant Armed. 
 
L## Perim Instant 
Default: 
Refer to the program record sheet 
Selection: 
Blank or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Perimeter Instant 
Arm 
[COMMAND][2] 
Instant arm all Perimeter points, including Delayed 
points, only in the area where the keypad is assigned. 
This function ignores the A# FA Bypass 
Max
 entry in Area Parameters. 
 
 
Local Only Reporting:  No Closing 
Report is sent to the central station, but a 
Perimeter Delay Closing Event is 
 
generated in the event log. 
 
L## View Area Stat 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
View Area Status  (Menu function 
only) 
View the current arm or disarm status and the not 
ready to arm status of all areas within the scope of the 
keypad in this area. The user needs arming and 
disarming authority.