Installation Clearances
Venting Requirements 
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed 
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use a 6" (15.2 cm) or larger round metal vent or a 3
¹⁄₄" x 10" 
(8.3 x 25.4 cm) rectangular metal vent. Rigid metal vent is 
recommended. Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be 
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent 
between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has a 
damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the 
cap.
Cold Weather Installations
An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of make up air systems 
when using ventilation systems greater than specified CFM of air 
movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.
Venting Methods
Vent system can terminate either through the roof or wall. Use 
3
¹⁄₄" x 10" (8.3 x 25.4 cm) with a maximum vent length of 
35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a maximum 
length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that gently reduces 
performance. 
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 24" (61.0 cm) min. for electric cooking surfaces
27" (68.6 cm) min. for gas cooking surfaces
30" (76.2 cm) suggested max. - bottom of range hood to 
cooking surface
C. 30" (76.2 cm) min. cabinet opening width
D. 13" (33.0 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
A
B
C
D
E
Roof Venting
Wall Venting
A. 6" (15.2 cm) or larger round 
vent or a 3
¹⁄₄" x 10" (8.3 x 
25.4 cm) rectangular vent 
through roof
B. Round vent: use 6" (15.2 cm) 
or larger round damper
(purchased separately)
C. Round vent: use 3
¹⁄₄" x 10" 
(8.3 x 25.4 cm) to 6" (15.2 cm) 
or larger diameter transition 
piece
(purchased separately)
D. 27" (68.6 cm) - 30" (76.2 cm) 
above gas cooking surface
24" (61.0 cm) - 30" (76.2 cm) 
above electric cooking 
surface
E. Roof cap
A. 6" (15.2 cm) or larger round 
vent or a 3
¹⁄₄" x 10" (8.3 x 
25.4 cm) rectangular vent 
through the wall
B. Round vent: use 3
¹⁄₄" x 10" (8.3 
x 25.4 cm) to 6" (15.2 cm) or 
larger diameter transition piece
(purchased separately)
C. 3
¹⁄₄" x 10" (8.3 x 25.4 cm) 
through the wall
D. 27" (68.6 cm) - 30" (76.2 cm) 
above gas cooking surface
24" (61.0 cm) - 30" (76.2 cm) 
above electric cooking surface
E. Wall cap
A
B
D
C
E
A
B
C
D
E