Kenwood M) 用户手册

下载
页码 42
TK-2160
40
LEVEL DIAGRAM
C365
C475
Q404
–119.5dBm
–117.0dBm
–115.0dBm
–106.0Bm
–118.0dBm
IC601
500mW
16mV
rms
VCO
C44
16mV
rms
320mV
rms
12.6dBm
C441
C417
XF401
RF (CENTER FREQUENCY)
IF1 (49.95MHz)
IF2
(450kHz)
AF
(1kHz)
IC605
C645
C648
C85
C81
AF (1kHz)
RF (CENTER FREQUENCY)
RXLO
D401
D201
2dBm
C246
31.8dBm
C344
4.8W
RF (CENTER FREQUENCY)
AF (1kHz)
RX
TX
2.7dBm
C203
PLL
FM IF
SYSTEM
–104.0dBm
217mV
rms
358mV
rms
C414
IC602
IC401
AQUA
IC601
AQUA
Q206
Q207
Q211
To
 make measurements in the AF section, connect
the AC level meter
. (ANT input : -53dBm, 1kHz FM,
3kHz DEV(WIDE).)
In the RF section, use a 1000pF coupling capacitor
.
(The display shows the SSG input value required to
obtain 12dB SINAD Without Local Level.)
AG is set to the MIC input becomes 3kHz DEV
. at
1kHz MOD. (WIDE)
To
 make measurements in the AF section, connect
the AC level meter
.
In the RF section, use a 1000pF coupling capacitor
.