GE GTV21ESSJWW 安装指导

下载
页码 8
Installation Instructions
8
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 in. 
(107 cm) of your washer’s water inlet. The faucets MUST 
EH  LQ   FP  JDUGHQ KRVHW\SH VR LQOHW KRVHV FDQ
be connected. Water pressure MUST be between 10 and 
120 pounds per square inch. Your water department can 
advise you of your water pressure.
NOTE: A water softener is recommended to reduce buildup 
of scale inside the steam generator if the home water 
supply is very hard.
12
 CONNECTING INLET HOSES 
(on some 
models)
To produce steam, the dryer must connect to the cold 
water supply. Since the washer must also connect to the 
cold water, a “Y” connector is inserted to allow both inlet 
hoses to make that connection at the same time.
NOTE: Use the new inlet hoses provided; never  use old 
hoses.
1.  7XUQWKHFROGZDWHUIDXFHWRȺ5HPRYHWKHZDVKHULQOHW
KRVHIURPWKHZDVKHU¿OOYDOYHFRQQHFWRU FROG 
2.  (QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGVFUHZWKH
IHPDOHFRXSOLQJ RIWKHVKRUWKRVHRQWR WKHZDVKHU¿OO
YDOYHFRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
3.  Attach the female end of the ‘’Y’’ connector to the male 
FRXSOLQJRIWKHVKRUWKRVH(QVXUHWKHUXEEHUÀDWZDVKHU
LVLQSODFH7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
4.  ,QVHUWWKH¿OWHUVFUHHQLQWKHFRXSOLQJRIWKHZDVKHU·V
LQOHW KRVH ,I D UXEEHU ÀDW ZDVKHU LV DOUHDG\ LQ SODFH
UHPRYHLWEHIRUHLQVWDOOLQJWKH¿OWHUVFUHHQ$WWDFKWKLV
coupling to one male end of the ‘’Y’’ connector. Tighten 
E\KDQGXQWLO¿UPO\VHDWHG
5.  (QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFKWKH
dryer’s long inlet hose to the other male end of the ‘’Y’’ 
FRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
6.  (QVXUH WKH UXEEHU ÀDW ZDVKHU LV LQ SODFH DQG DWWDFK
WKH RWKHU HQG RI WKH GU\HU·V ORQJ LQOHW KRVH WR WKH ¿OO
valve connector at the bottom of the dryer back panel. 
7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
12
 CONNECTING INLET HOSES (cont.)
7.  Using pliers, tighten all the couplings with an additional 
two–thirds turn.
NOTE: Do not overtighten. Damage to the couplings may 
result. 
8.  Turn the water faucet on.
9.  Check for leaks around the ‘’Y’’ connector, faucet and 
hose couplings.
13
 SERVICING
     WARNING - 
LABEL ALL WIRES 
PRIOR TO DISCONNECTING WHEN 
SERVICING CONTROLS. WIRING 
ERRORS CAN CAUSE IMPROPER AND 
DANGEROUS OPERATION AFTER 
SERVICING/INSTALLATION.
For servicing phone numbers for replacement parts, and 
other information, refer to Owner’s Manual or visit our 
Web site.
5(*,67(5<2851(:$33/,$1&(725(&(,9($1<
,03257$17352'8&7127,),&$7,216
Please go to www.GEAppliances.com or mail in your 
3URGXFW5HJLVWUDWLRQ&DUG
For questions on installation, call: 800.626.2000 (US) or 
 &DQDGD