Instructions for the installer
 
 
31 
 
 
5.3 
Regulation for natural gas 
 
   
 
 The hob has been inspected for G20 (2H) natural gas at a pressure of 
20 mbar. To allow the unit to work with this type of gas, perform the 
same operations described in paragraph “5.2
 
Regulation for LPG”, but 
choose the nozzles and regulate the primary air for natural gas, as 
shown in the following table and in paragraph “5.5
 
Regulation of 
primary air”. After the regulations have been carried out, restore the 
seals with sealing wax or equivalent material. 
Burner 
Rated heating 
capacity 
Natural gas – G20 20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary (1) 
1.05 
73 
380 
Semirapid (2) 
1.65 
92 
380 
Rapid (3) 
2.55 
115 
650 
Rapid large (4) 
3.1 
126 
750 
Fish pan (7) 
2.0 
100 
750 
Ultra rapid (5) 
3.3 
130 
1200 
Internal 
1.05 
73 
380 
Double 
crown 
(6) 
External 
3.9 
140 
1200 
 
 
5.4 
Regulation for town gas 
 
 
 
 
 
 
 To allow the unit to work with this type of gas, perform the same 
operations described in paragraph “5.2
 
Regulation for LPG”, but 
choose the nozzles and regulate the primary air for town gas, as shown 
in the following table and in paragraph “5.5
 
Regulation of primary air”. 
Attention! Only units with safety valves can be used with town gas 
G110. 
Burner 
Rated heating 
capacity 
Town Gas 110 - 8 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary (1) 
1.05 
132 
380 
Semirapid (2) 
1.65 
165 
380 
Rapid (3) 
2.55 
210 
650 
Rapid large (4) 
3.1 
240 
750 
Fish pan (7) 
190 
750 
Ultra rapid (5) 
3.3 
250 
1200 
Internal 
1.05 
132 
380 
Double crown 
(6) 
External 
3.9 
290 
1200