Bertazzoni X)486GPIRVI 用户手册
22
STEP 3: MINIMUM FLAME ADJUSTMENT
WARNING!
These adjustments should be made only for use
of the appliance with natural gas. For use with
liquid propane gas, the choke screw must be
fully turned in a clockwise direction.
SURFACE BURNERS
1. Light one burner at a time and set the knob
to the MINIMUM position (small flame).
2. Remove
the
knob.
3. The range is equipped with a safety valve.
Using a small‐size slotted screwdriver, locate
the choke valve on the valve body and turn
the choke screw to the right or left until the
burner flame is adjusted to desired minimum.
the choke valve on the valve body and turn
the choke screw to the right or left until the
burner flame is adjusted to desired minimum.
4. Make sure that the flame does not go out
when switching quickly from the MAXIMUM
to the MINIMUM position.
to the MINIMUM position.