Bertazzoni X)486GPIRVI 用户手册

下载
页码 52
 
22
 
 
STEP 3: MINIMUM FLAME ADJUSTMENT 
 
WARNING! 
These adjustments should be made only for use 
of the appliance with natural gas. For use with 
liquid propane gas, the choke screw must be 
fully turned in a clockwise direction. 
 
SURFACE BURNERS 
1.  Light one burner at a time and set the knob 
to the MINIMUM position (small flame). 
2. Remove 
the 
knob. 
3.  The range is equipped with a safety valve. 
Using a small‐size slotted screwdriver, locate 
the choke valve on the valve body and turn 
the choke screw to the right or left until the 
burner flame is adjusted to desired minimum. 
4.  Make sure that the flame does not go out 
when switching quickly from the MAXIMUM 
to the MINIMUM position.