Smeg SCA130P 用户手册

下载
页码 28
Instructions for the User
24
12.6.5 Setting the cleaning cycle with electronic analogue clock
  
  
FUNCTION SELECTOR KNOB
CLEANING CYCLE DURATION
Turn the function selector knob to the 
 symol. The segments relating to the 90 minutes after the
current time will illuminate on the display. Press the 
 keywithin 1/2 seconds to increase the duration of
this operation up to a maximum of three hours. 6/7 seconds after the knob has been turned to the 
symbol or the pyrolysis duration has been set, the oven will start the cycle. The internal and external
segments on the display will flash in alternation, and finally they will go out, to be replaced by constant
display of the current time. The segments will continue to flash until the end of the pyrolysis.
The start of the pyrolysis cycle can be programmed within the next 12 hours. After setting the pyrolysis
duration, press the 
 key and set the pyrolysys start time by pressing the 
 / 
 keys. The internal
segments will remain on and the external ones will flash until the current time is the same as the cycle
start time. The process will now start and the segments will start to flash as already described.