Smeg FS61MFX 用户手册

下载
页码 36
 
 
Instructions for the user 
 
 
21 
8.  USE OF THE HOB 
 
8.1  Lighting of the hob burners 
  Before  lighting  the  hob  burners  check  that  the  flame  caps  are  in  the 
correct position and that their burner caps are in place, making sure that 
the  holes  A  in  the  flame  caps  correspond  to  the  spark  plugs  and 
thermocouples. 
 
Before  lighting  the  burners  lift  the  glass  cover;  before  lowering  the 
cover, turn off all the burners and wait for them to cool down. 
  
 
  The optional grid B is for use with “woks” (Chinese pans).  
To prevent deterioration of the hob  we have equipped the cooker with a 
raised  pan  stand C  to be  placed  underneath  pans more than 26 cm in 
diameter. 
 
The supplied reduction rest C is also used for small pans. 
 
 
 
 
The  drawing  next  to  each  knob  shows  the 
corresponding  burner.  The  appliance  has  an 
electronic  lighting  device.  Simply  press  and  turn 
the  knob  anticlockwise  to  the  minimum  flame 
symbol 
, until the ring is lit. Hold the knob down 
for  a  few  seconds  to  allow  the  thermocouples  to 
heat up. The burner may go out when the knob is 
released:  this  is  because  the  thermocouple  has 
not been sufficiently heated. Repeat the operation 
holding  down  the  knob  for  a  little  longer.  This 
operation  is  not  necessary  for  burners  without 
thermocouples. 
 
 
For models with thermocouples, if the burner should accidentally go out, 
a safety device will be activated which stops the gas flow even if the tap 
is open.