Jet Tools -20QT-3 用户手册

下载
页码 52
 
8
Models JWBS-18-3, -20QT-3, -20QT-5 
Band saw models JWBS-18QT-3, JWBS-20QT-
3 and JWBS-20QT-5 are wired from the factory 
for 230 volt operation only. Refer to 
Specifications for phase and HP ratings. 
A plug is not included. You may either install a 
plug or “hard-wire” the band saw directly to a 
control panel. 
If connecting a plug, use a proper UL/CSA listed 
2-pole, 3-wire grounding plug suitable for 230V 
operation.  
If the band saw is to be hard-wired to a panel, 
make sure a disconnect is available for the 
operator. During hard-wiring of the band saw, 
make sure the fuses have been removed or the 
breakers have been tripped in the circuit to 
which the band saw will be connected. Place a 
warning placard on the fuse holder or circuit 
breaker to prevent it being turned on while the 
machine is being wired. 
 
Circuit Information 
The Band Saw should be connected to a 
dedicated circuit with a circuit breaker or time 
delay fuse with the appropriate amperage rating. 
See Table 1 for recommended circuit sizes. 
NOTE: These are recommendations only – all 
local codes must be given priority.
 
 
 
Extension cords 
The use of an extension cord is not 
recommended for this band saw. Try to position 
your machine within reach of the power supply. 
If an extension cord becomes necessary, make 
sure the cord rating is suitable for the amperage 
listed on the machine’s motor plate. An 
undersized cord will cause a drop in line voltage 
resulting in loss of power and overheating. 
Use the chart in Table 2 as a general guide in 
choosing the correct size cord. If in doubt, use 
the next heavier gauge. The smaller the gauge 
number, the heavier the cord. 
 
 
Model Voltage 
Recommended 
Circuit* 
JWBS-18QT 
710750B 
115V 40A 
230V 20A 
JWBS-18QT-3 
710751B 
230 30A 
JWBS-20QT-3 
708754B 
230 30A 
JWBS-20QT-5 
708755B 
230 50A 
* Local codes take precedence over recom-
mendations. 
Table 1 
 
Recommended Gauges (AWG) of Extension Cords 
Amps 
Extension Cord Length * 
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 to 20 
10 
10 
10 
NR 
NR 
NR 
21 
to 
30  10  NR NR NR NR NR 
 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended.
 
Table 2