StorageTek SCSI-3 用户手册

下载
页码 45
FCP and SES Commands
3-6
8946121402
Switch Page
If requested using the
Send Diagnostic
or
Receive Diagnostic Result
command, the
SESD returns the response shown in
2
(MSB)
                            Page Length = 7                                                     (LSB)
3
4
00h
5
80h
6
81h
7
82h
8
83h
9
84h
10
85h
Table 3-10  Switch Page Format
Byte/Bit
Field #
Access
7
6
5
4
3
2
1
0
0
na
na
Page Code = 80h
1
na
na
Reserved
2 .. 3
na
na
Page Length = 404
4 .. 7
na
na
swValid
8 .. 71
0
ro
Current_Date (in ASCII text)
72 .. 135
1
ro
Boot_Date (in ASCII text)
136 .. 199
2
ro
Firmware_Last_Updated_Date (in ASCII text)
200 .. 263
3
ro
FLASH_Last_Updated_Date (in ASCII text)
264 .. 327
4
ro
Boot_PROM_Last_Updated_Date (in ASCII text)
328 .. 391
5
ro
Firmware_Version_Information (in ASCII text)
392 .. 395
6
ro
Switch_Operational_Status
396 .. 399
7
rw
Switch_Administrative_Status
400 .. 403
8
ro
Diagnostics_Result
404 .. 407
9
ro
Number_of_Sensors
Note: na is not available, ro is read only and rw is read/write
Table 3-9  Page Code 0 Format – Supported Diagnostic Pages (Continued)
Byte/Bit
7
6
5
4
3
2
1
0