3M 800af 用户手册

下载
页码 94
17
Operation
 
(Continued)
3
Emergency "Stop" Switch
The two emergency "Stop" switches are
mounted for operator convenience, on both
sides of the case sealer. Pushing either of
these switches will stop the drive motors/belts
and exhaust air from the flap kicker.
To restart machine, rotate emergency stop
switch (release switch latch) and then restart
machine by pressing green (On) button on side
guard.
4
Height Adjustment Crank, Upper
Taping Head
Raises and lowers upper taping head/flap
folders to accommodate box height.
5
Width Adjustment Crank
Adjusts distance between side drive belts to
accommodate box width.
6
Top Flap Compression Rollers
Rollers adjust to properly maintain box width/
top flap center seam for tape seal.
7
Indicator, Air Pressure
The optical warning indicator, located on the
upper flap folder frame, indicates "Red" when
compressed air circuit is on.
8
Box Gate Air Pressure Regulator
Adjusts lifting force of the box gate depending
on the weight of boxes being sealed.
9
Gate Cams Figure 3-4
The gate cams   A    B   control the rate of box
entry into the case sealer.  Depending on box
size, gate cams can be adjusted to increase
production rate.  See "Adjustments – Gate
Operation", page 29.
10 Kicker Cam Figure 3-4
The minor flap folder, controlled by the kicker
cam  C  , closes the trailing minor flap on the
box.  The kicker cam must be adjusted
according to the length of the box being
sealed.  See "Operation", page 20,
Figure 3-8.
11
Pocket, Instruction Manual
A pocket is provided inside the right door for
storage of the machine instruction manual.
Keep the manual in this pocket for the
convenience of machine operators.
Figure 3-4 – Gate/Kicker Cams
Figure 3-3 – "On/Off" Valve/Regulator/Filter