3M C3266PW 用户手册

下载
页码 56
3M™ Multi-Touch Chassis Display User Guide 
 
37 
 
3M Touch Systems, Inc. Proprietary Information – TSD-39373 REV E
 
Table 7. Power On Check Bit Fields 
Bit Number 
Description 
Notes 
Not used 
 
ROM_ERROR 
Code area checksum error 
PWM Error      
Touch screen not connected or potential problem 
NOV_ERROR 
Parameter blocks checksum error 
HDW_ERROR 
Problem with ADCs 
5--7 
Not used 
 
Command Status – The status for the last command request. This field is used to 
determine whether the last request was processed successfully. It is also used to track the 
progress of a multi-stage request, such as 2 point calibration. The Status Request does 
not affect the contents of this field, i.e., successful or unsuccessful processing of a 
previous status request does not cause the command status field to be updated. 
Table 8. Valid Command Status Field Entries 
Response 
Description 
Failure in command processing 
Command being processed 
Stage 1 processing complete (for multi-stage commands) 
Command complete 
4  
Soft Reset Occurred 
Hard Reset Occurred 
6 -- 7 
Not used 
Get Feature - GetMaxCount 
This is a request to send information that indicates the maximum number of 
simultaneous touches supported by the controller. 
Table 9. Setup Stage 
Offset  Field 
Size 
Value 
Description 
bmRequestType 
0xA1 
Class,D2H,Interface 
bRequest 
0x01 
Get Report 
wValue 
0x0312  msb=03=Feature  
lsb=12 Feature Report ID 
wIndex 
Always 0 
wLength 
Always 2 
 
 
 
 
 
Table 10. Data Stage (controller response) 
Offset  Field 
Size 
Value 
Description 
Report ID 
0x12 
Feature Report ID  
Max Count 
0x1E 
Number of actual fingers supported 
Note:
  The number of actual contacts reported may exceed this number.