Vermont Casting DVT38S2 用户手册

下载
页码 40
6
Chateau™ Decorative Gas Appliance
20009543
Framing and Finishing
NOTE: The valve box assembly must be installed in 
the same room as the fireplace.
1.  Choose the unit location.
2.  The unit is shipped with four (4) nailing flanges 
mounted near the front corners on the side with the 
valve box assembly . (Fig. 4)
3.  Frame the fireplace with a header across the top of 
the standoff. (Fig. 5) It is very important to allow for 
the finished wall face along with marble, tiles or any 
other noncombustible face finish material desired 
when setting the depth of the framing.
4.  Attach the fireplace nailing flanges to the frame as 
shown in Figure 4.
5.  The gas components are located in the control 
panel assembly attached to the right side of the unit. 
Choose the desired location on the wall or mantel 
for the valve box assembly. The conduit length is 5’ 
(1524 mm). (Fig. 6) The framing dimensions for the 
box are 12¹⁄₄”L x 9¹⁄₄”W x 5⁵⁄₈”D (311 x 235 x 143 mm). 
When the framing for the box is complete, remove 
the screws securing the valve box to the outer cas-
ing. Carefully remove the valve box and, without 
stressing the conduit, slide the box into the framed 
opening. Replace the screws removed from the side 
of the outer casing.
6.  To secure the valve box assembly to the framing 
members, open the box door, remove extension 
knob(s), remove the valve cover by removing the 
two (2) screws securing the valve cover to the box, 
hold the cover plate with one hand and disconnect 
the wires to the switch and pilot indicator (R models 
only). NOTE:  Do not allow the valve cover plate to 
hang from the pilot indicator wires as this could dam-
age the wires. Secure the box to the framing through 
the two (2) holes at the top and one (1) on each 
side using sheet rock screws. (Fig. 7) After fram-
ing the box, replace the wires, the valve cover, the 
extension knob(s) in reverse order. NOTE: The pilot 
indicator body is labelled +/-, make sure the positive 
wire on the pilot indicator goes to ground and the 
negative goes to the plug between the valve and the 
thermocouple.
7.  The U-channel located on the top of the unit as well 
as the nailing flanges on the sides that were men-
tioned in Step 1, are designed to accommodate non-
combustible board (recommended Dura-Rock). They 
are positioned 1” (25mm) back from the face of the 
unit. NOTE: The U-channel depth can be adjusted 
by loosening the hex nut inside the channel.
FP1357b
DVT38s2nailing flanges
3/17/04   djt
6"
(152 mm) Min.
1"
(25 mm) Min.
1���"
(38mm) 
Max. Hearth Height
FP1357a
Fig. 4   Nailing flanges.
Bend 
Line
FP1467a
DVT38s2
framing
6/05   djt
1"
(25 mm)
6"
(152 mm)
Fig. 5   Fireplace framing.
FP1467a
FP1361
Fig. 6  Valve box assembly location.
������������
������������
������
���������������
��������
�������������