To prevent possible SERIOUS INJURY or DEATH from 
electrocution:
•  Be sure power is NOT connected BEFORE installing door 
control.
• Connect ONLY to 24 VOLT low voltage wires. 
To prevent possible SERIOUS INJURY or DEATH from a 
closing garage door:
•  Install door control within sight of garage door, out of reach 
of children at a minimum height of 5 feet (1.5 m) and away 
from ALL moving parts of door.
•  NEVER permit children to operate or play with door control 
push buttons or remote control transmitters.
•  Activate door ONLY when it can be seen clearly, is properly 
adjusted and there are no obstructions to door travel.
•  ALWAYS keep garage door in sight until completely closed. 
NEVER permit anyone to cross path of closing garage door.
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door at a minimum 
height of 5 feet (1.5 m) where small children cannot 
reach, and away from moving parts of door and door 
hardware. The installation surface must be smooth and 
flat. If installing into drywall, drill 5/32" holes and use 
anchors provided. For pre-wired installations (as in new 
home construction), it may be mounted to a single gang 
box (Figure 1). NOTE: After installation, a green or 
amber indicator light behind the cover will indicate proper 
connection. If not lit, the Lock and Light features will not 
function (reverse wires to correct).
1.  Strip 7/16" (11 mm) of insulation from one end of bell 
wire and connect to the two screw terminals on back of 
door control by color: white wire to WHT and white/red 
wire to the RED (Figure 2).
2.  Remove white cover by gently prying on a side corner 
near the top of the cover with a small flat head 
screwdriver (Figure 3). Fasten with 6ABx1-1/4" 
self-tapping screws (drywall installation) or 6-32x1" 
machine screws (into gang box) as follows:
  •  Drill and install bottom screw, allowing 1/8"(3 mm) to 
protrude above wall surface.
  •  Position bottom of door control on screw head and 
slide down to secure. Adjust screw for snug fit.
  •  Install top screw with care to avoid cracking plastic 
housing. Do not overtighten.
  • Insert bottom tabs and snap on cover (Figure 4). 
  
NOTE: The push bar may stick if the door control is 
not mounted on a smooth surface. If a click is not 
heard when pressing the push bar, loosen the two 
mounting screws or relocate the door control to a 
smoother surface.
3.  (Standard installation only) Run bell wire up wall and 
across ceiling to motor unit. Use insulated staples to 
secure wire in several places. Do not pierce wire with 
a staple, creating a short or open circuit. 
4.  Strip 7/16" (11 mm) of insulation from end of bell wire. 
Connect bell wire to the quick-connect terminals as 
follows: white to white and white/red to red (Figure 5).
  
NOTE: When connecting multiple door controls to the 
opener, twist same color wires together. Insert wires 
into quick-connect holes: white to white and red/white 
to red.
5.  Use tacks or staples to permanently attach entrapment 
warning label to wall near door control, and manual 
release/safety reverse test label in a prominent 
location on inside of garage door.
NOTE: DO NOT connect power and operate opener at 
this time. The trolley will travel to the full open position 
but will not return to the close position until the sensor 
beam is connected and properly aligned.
Drywall Anchors
Insulated
Staples 
Screw 6ABx1-1/4"
Screw 6-32x1" 
(pre-wired installation)
HARDWARE SHOWN ACTUAL SIZE
Figure 2
To Replace
Insert Bottom Tabs First
PRE-WIRED 
INSTALLATION
LOCK
LIGHT
24 Volt
2-Conductor
Bell Wire in 
Gang Box
LOCK
LIGHT
To Replace
Insert Bottom Tabs First
WHT
RED
 Bell Wire
Terminal 
Screws
 Bottom Mounting Hole
 Top Mounting Hole
DOOR CONTROL (BACK)
To insert or release wire, push 
in tab with screwdriver tip
Door Control
Connections
7/16" (11 mm)
Strip wire 7/16" (11 mm)
Red
Grey
White
KG
1
3
9
7
5
KG
1
3
9
7
5
Figure 5
Figure 1
Figure 3
Figure 4
Figure 2