Chamberlain WD832KD 1/2 HP 用户手册

下载
页码 40
4
Safety Reversing Sensor
Header Wall
Access Door
 — — —        — — —        — —
Safety
Reversing
Sensor
Gap between floor 
and bottom of door
must not exceed 1/4" (6 mm).
Extension Spring
Horizontal and vertical reinforcement
is needed for lightweight garage doors
(fiberglass, steel, aluminum, door with
glass panels, etc.). See page 23 for details.
Support bracket & 
fastening hardware
is required.
See page 16.
FINISHED CEILING
Motor unit
Wall-
mounted
Door 
Control
OR
Torsion Spring
Vertical
Centerline
of Garage Door
SECTIONAL DOOR INSTALLATION
Planning
Identify the type and height of your garage door. Survey
your garage area to see if any of the conditions below
apply to your installation. Additional materials may be
required. You may find it helpful to refer back to this page
and the accompanying illustrations as you proceed with
the installation of your opener.
Depending on your requirements, there are several
installation steps which may call for materials or
hardware not included in the carton.
• Installation Step 1 – Look at the wall or ceiling above
the garage door. The header bracket must be securely
fastened to structural supports.
• Installation Step 5 – Do you have a finished ceiling in
your garage? If so, a support bracket and additional
fastening hardware may be required.
• Installation Step 10 – Depending upon garage
construction, extension brackets or wood blocks may
be needed to install sensors.
• Installation Step 10 – Alternate floor mounting of the
safety reversing sensor will require hardware not
provided.
• Do you have an access door in addition to the garage
door? If not, Model 7702CB Emergency Key Release
is required. See Accessories page.
CLOSED POSITION 
Header 
Wall 
Garage 
Door 
Header 
Bracket 
Trolley 
Straight 
Door 
Arm 
Emergency Release 
Rope & Handle 
Door 
Bracket  
Curved 
Door 
Arm 
Garage 
Door 
Spring 
Belt 
Trolley  
Stop Bolt 
• Look at the garage door where it meets the floor. Any
gap between the floor and the bottom of the door must
not exceed 1/4" (6 mm). Otherwise, the safety reversal
system may not work properly. See Adjustment Step 3.
Floor or door should be repaired.
SECTIONAL DOOR INSTALLATIONS
• Do you have a steel, aluminum, fiberglass or glass
panel door? If so, horizontal and vertical 
reinforcement is required (Installation Step 11). 
• The opener should be installed above the center of the
door. If there is a torsion spring or center bearing plate
in the way of the header bracket, it may be installed
within 4 feet (1.22 m) to the left or right of the door
center. See Installation Steps 1 and 11.
• If your door is more than 7 feet (2.13 m) high, see rail
extension kits listed on Accessories page.