JAI AD-081GE 用户手册

下载
页码 82
AD-081GE 
10 
5.4.      DIP switches 
              DIP switches are located inside the camera. When the top cover is removed, please pay 
careful attention so that the boards inside may not be damaged. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5.4.1      Trigger input 75 ohms termination 
                Trigger input can be terminated with 75 ohms if DIP switch SW600 is selected as 
described below. Factory default is TTL. 
TTL
75 Ω
 
 
5.4.2      EEN output 
                EEN output through HIROSE 6-pin #4 can be selected TTL level or open collector level.   
The selection is activated by DIP switch SW100 described below. Factory default is   
TTL. 
TTL
OPEN
 
 
 
5.4.3      Video output for Auto iris lens 
             
The output through HIROSE 12-pin #4 can be selected OPT IN 2 or Iris video output by DIP 
switch SW700 described below. Factory default is OPT IN 2. 
           
OPT IN
IRIS
 
 
 
 
 
 
SW700 for lens iris 
SW600 for 75 ohms 
termination   
SW100 for selecting 
EEN output 
① 
TTL IN 1 
② 
TTL IN 2