JAI AD-081GE 用户手册

下载
页码 82
AD-081GE 
13 
8.      GPIO (Inputs and outputs)     
8.1.      Overview 
All input and output signals pass through the GPIO (General Purpose Input and Output) module. 
The GPIO module consists of a Look-Up Table (LUT – Cross-Point Switch), 2 Pulse Generators 
and a 12-bit counter. In the LUT, the relationship between inputs, counters and outputs is 
governed by internal register set-up. 
LUT
( Cross Point Switch )
Pulse Generator 3
(20 bit Counter  )
Pulse Generator 2
(20 bit Counter  )
12 bit
Counter
TRIGGER  1 -0
TRIGGER  1 -1
TTL OUT 1
OPT OUT 1
OPT OUT 2
Time Stamp Reset
Sequence Reset
LVAL IN 1
DVAL IN 1
FVAL IN 1
EEN IN 1
OPT IN 1
OPT IN 2
TTL IN 2
LVDS IN 1
Soft Trigger 0
Soft Trigger 1
Soft Trigger 2
Soft Trigger 3
Pulse trigger IN
Pulse OUT
Pulse Generator 0
Pulse Generator 1
Pulse Generator 2
Pulse Generator 3
Digital I/O(GPIO) setting
Digital I/O(GPIO) setting
Setting for 
Line Source
Setting for 
Line Selector
Pixel Clock
Counter Clock Source
1
Counter Divide by value
Bypass
0
1 - 4095
Pulse Generator Setting 0
Start Point Counter 0 ( 1)
Length counter 0
Start Point Counter 0 (2) for repeat
End point counter 0
Counter 0 clear
Pulse Generator Setting 2
Pulse Generator 0
(20 bit Counter  )
Pulse Generator 1
(20 bit Counter  )
Pulse Generator Setting 1
Pulse Generator Setting 3
TRIGGER  2 -1
TRIGGER  2 -0
Sequence Reset
Pulse Generator 1
Pulse Generator 0
LVAL IN 2
TTL IN 1
EEN IN 2
FVAL IN 2
DVAL IN 2
Pulse Generator 2
Pulse Generator 3
 
 
Some of the descriptions in this diagram differ from those displayed in the camera control tool. 
The following table shows display names and descriptions. 
Line Source 
Line Selector 
Description 
Display Name 
Description 
Display Name 
OPT IN 1 
Line 4 
TTL OUT 1 
Line 1 
OPT IN 2 
Line 5 
OPT OUT 1 
Line 2 
TTL IN 1 
Line 6 
OPT OUT 2 
Line 3 
TTL IN 2 
Line 7 
 
 
LVDS IN 1 
Line 8 
 
 
 
On the above block diagram, Trigger 0 is used for Exposure and Trigger 1 is used for Delayed 
Readout.    The Time Stamp Reset can reset the time stamp compliant with the GigE Vision 
standard. This is used for ensuring the same time stamp if multiple cameras are used. 
 
The blocks shown in the above diagram have the following functionalities: