JAI AD-081GE 用户手册

下载
页码 82
AD-081GE 
21 
8.4.2      Internal Trigger Generator 
Example: Create a trigger signal and trigger the camera.    These are the settings for 
Imager 1. For Imager 2, trigger 2-0 should be set in the same manner.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig.15      Pulse Generator 0 timing Example 2 
 
Address 
Register 
Value 
 
0xA040 
Trigger Mode 
1 = EPS 
 
0xB000 
Clock Choice 
1 = Pixel Clock 
0xB004 
Counter Dividing Value 
1419= 1/1420(Line Rate) 
0xB008 
Length Counter 0 
1000 Clocks 
0xB00C 
Start point Counter 0 (1) 
100 Clocks 
0xB010 
Start point Counter 0 (2) 
0 = Infinite 
0xB014 
End point Counter 0 
500 Clocks 
0xB018 
Counter Clear 0 
0 = Free Run 
 
0xB060 
CAMERA TRIGGER Selector 
16 = pulse generator 0 
Pulse Generator 0
100 Line
500 Line
1000 Line
output
Pulse Generator 0
100 Line
500 Line
1000 Line
output
LUT
( Cross Point Switch )
Pulse Generator 3
(20 bit Counter  )
Pulse Generator 2
(20 bit Counter  )
12 bit
Counter
TRIGGER  1 -0
TRIGGER  1 -1
TTL OUT 1
OPT OUT 1
OPT OUT 2
Time Stamp Reset
Sequence Reset
LVAL IN 1
DVAL IN 1
FVAL IN 1
EEN IN 1
OPT IN 1
OPT IN 2
TTL IN 2
LVDS IN 1
Soft Trigger 0
Soft Trigger 1
Soft Trigger 2
Soft Trigger 3
Pulse trigger IN
Pulse OUT
Pulse Generator 0
Pulse Generator 1
Pulse Generator 2
Pulse Generator 3
Digital I/O(GPIO) setting
Digital I/O(GPIO) setting
Setting for 
Line Source
Setting for 
Line Selector
Pixel Clock
Counter Clock Source
1
Counter Divide by value
Bypass
0
1 - 4095
Pulse Generator Setting 0
Start Point Counter 0 
Length counter 0
Repeat Count 0 
End point counter 0
Counter 0 clear
Pulse Generator Setting 2
Pulse Generator 0
(20 bit Counter  )
Pulse Generator 1
(20 bit Counter  )
Pulse Generator Setting 1
Pulse Generator Setting 3
TRIGGER  2 -1
TRIGGER  2 -0
Sequence Reset
Pulse Generator 1
Pulse Generator 0
LVAL IN 2
TTL IN 1
EEN IN 2
FVAL IN 2
DVAL IN 2
Pulse Generator 2
Pulse Generator 3




1000clk
100clk
0
500clk
0 Free run