JAI AD-081GE 用户手册

下载
页码 82
AD-081GE 
49 
10.5.    Operation Mode 
AD-081GE has the following 8 operation modes and OB transfer and ROI modes.
 
 
Continuous   
Pre-selected exposure 
Edge Pre-Select Trigger   
Pre-selected exposure 
Pulse Width Control Trigger 
Pulse width controlled exposure 
Reset Continuous Trigger 
Pre-selected exposure 
PIV (Particle Image Velocimetry) 
 
Sequence EPS 
Pre-selected exposure 
Delayed readout EPS 
Pre-selected exposure 
8    Delayed readout PWC 
Pulse controlled exposure 
Smearless   
Effective for EPS and PWC 
10  OB transfer mode 
 
11  ROI mode 
 
 
 
10.5.1      Continuous mode 
For applications not requiring asynchronous external triggering, this mode should be used for 
continuous operation. 
For timing details, refer to fig. 33 through fig. 38.   
 
To use this mode   
 
Set function: 
Trigger mode 
Continuous 
 
Sync mode 
Sync, async, High transfer rate, High 
dynamic range, High S/N 
 
Output Select 
8-bit, 10-bit, 12-bit 
 
Scanning 
Full/Partial 
 
Vertical binning   
ON/OFF 
 
Shutter 
Programmable, Exposure Time Abs, 
Auto shutter 
 
Programmable Shutter 
0.5L to 792L (1L unit) 
 
Other functions