JAI AD-081GE 用户手册

下载
页码 82
AD-081GE 
57 
Important Notes: 
   
 When this mode is used, at first set the video sending flag to OFF (Acquisition end). Then set 
the trigger mode to “Continuous”. Then, set the shutter mode to “Sequential Trigger” mode. 
After setting those functions, set the video sending flag to ON (Acquisition start).   
 If the changes are done while the trigger is input, the order of the sequence might be shifted.   
The trigger mode should be changed while the trigger is not input and after change the 
setting, execute the sequence reset to send 0xC0f0 command. 
 In this mode, while the acquisition is ON, saving to user area 1 to 3 is not available.   
While this mode is in operation, the shutter mode (0xA000) should not be changed. 
 
10.5.7      Delayed Readout EPS and PWC Modes (EPS and PWC) 
This mode can be used to delay the transmission of a captured image. When several cameras 
are triggered simultaneously and connected to the same GigE interface, it allows the cameras 
to be read out in sequence, preventing congestion. 
The image data is not transmitted directly by the trigger 0 and is stored in the memory located 
at the Ethernet Interface.    By the falling edge of the soft trigger 1, the image data is output. 
This mode can work in EPS mode and PWC mode. 
 
Exposure
CCD output
Store in the 
GigE memory
Output from 
GigE
Trigger 0
CCD Photodiode
CCD Transfer gate
GigE memory
Ethernet output
Trigger 1
 
Fig.50    Delayed Readout Mode 
Example of setting 
 
0xA040  PS Delayed Readout (0x17)   
0xB060                  Trigger 0 select, e.g. 0x04 OPT IN 1 
0xB-064                Trigger 1 select, e.g. 0x05 OPT IN 2 
For the details of Registers, please refer to the Camera Register Map which is included in the 
SDK.