Lucent Technologies 555-230-024 用户手册

下载
页码 362
Performance Measurements
Issue 5    January 1998
14-11
555-230-024
— System Management includes the number of successful and 
unsuccessful logins, the number of valid and invalid passwords, 
and the number of times a login name was valid but three 
successive invalid passwords were entered.
— Call Processing lists the number of valid and invalid barrier codes 
entered, and the number of valid and invalid authorization codes 
entered for the total system, the stations on the system, all tie 
trunks, all remote access trunks, and the attendant consoles. In 
addition, the time and dial access code/extension from which the 
last ten violations occurred are recorded.
— Maintenance Board lists the number of valid and invalid attempts to 
access the maintenance board.
Tandem Traffic report, which provides information on facilities that serve 
tandem traffic.
The following measurements are useful in helping you evaluate the network engi-
neering design for possible reconfiguration. They can help you decide how to 
reconfigure networks for lower-cost operation.
Hunt Group Measurements lists various information including the number 
of calls that overflowed the group queue.
Automatic Route Selection Pattern Measurements collects information on 
Automatic Route Selection patterns from when the report was 
administered into the measured pattern list until it is removed from the 
measured pattern list.
Trunk Group Detailed Measurements reports on the traffic on a selected 
subset of trunk groups for a sequence of 24 measurement intervals whose 
length is customer-selectable between the options of 15 minutes, 30 
minutes, and one hour. The report is divided into two sections:
— Group Identification includes the trunk group number, size, type, 
direction, and size.
— Measurements lists total usage, maintenance usage, total calls, 
incoming calls, tandem calls, group overflow, calls queued, queue 
overflow, percentage of all trunks busy, and percentage of outgoing 
blocking. 
The following measurements and reports are needed for engineering and load 
balancing a large switch. These measurements include:
Blockage Study report, which shows the blockages that occur for Time 
Division Multiplexing attempts and for Center Stage Switch connections 
for each port network and the blockages that occur between each pair of 
switch nodes.
Port Network and Link Usage is used in balancing load between port 
networks and in engineering links (Expansion Port Network/Switch Node), 
especially remote Expansion Port Networks over Digital Signal Level 1