Program 76-2 (X-Z) – WSIU, TSIU and RSIU / RSIS / RMDS Transmission Rates
Strata DK Programming     5/00
3-163
System & Station
Program 76-2 (X-Z) – WSIU, TSIU and RSIU / RSIS / 
RMDS Transmission Rates
Processor Type:
DK14, DK40i, all RCTUs and BCUs 
Program Type:
System
Initialized Default:
 All ports 2400 bps
Program 76-2 Overview
Assigns each installed WSIU (DK14 only), TSIU (DK40i only) or RSIU port to operate at a 
specified transmission rate. Where X identifies the WSIU, TSIU port number 1~2 or RSIU/RSIS/
RMDS port number 1~4 and Z identifies the WSIU, TSIU or RSIU/RSIS/RMDS port data 
transmission rate in bits-per-second (bps).
Whenever uploading Program 76 with DKi Admin/DKi Backup, the bps rate of the DKi Backup/
DKi Admin customer database (on the PC) and the WSIU, TSIU or RSIU/RSIS/RMDS TTY/
RMDS port must all be set the same. If the bps rate of these items are not the same, uploading 
Program 76 will fail.
The sum of the transmission rates of equipped WSIU, TSIU or RSIU/RSIS/RMDS ports cannot 
exceed 9600 bps. Ports assigned “no-function” (code 0) in Program 76-2X-Y will not be included 
in the transmission rate sum. The RMDS will only function at 1200 or 2400 bps on the DK424 or 
DK424i (see Program 77-1 LED 15).
Program 76-2 does not require system power Off/On to change the bps rate.
✱  ✱  ✱ ✱  6SNU   +ROG  6SNU 
+ROG  6SNU   +ROG  6SNU   +ROG
Port Number (x)
Data Transmission Rate (z)
1
2
3
4
Total 
Note
Total must be 
 9600 bps
.
Z=Transmission Rate (1~4):
1 = 9600 bps
2 = 4800 bps
3 = 2400 bps
4 = 1200 bps
SELECT = 2
X=Port (1~4)