System & Station
Program 22 – RPCI and DIU Station Hunting for Data Calls
Strata DK Programming     5/00
3-63
System & Station
Program 22 – RPCI and DIU Station Hunting for Data 
Calls
Processor Type:
DK14, DK40i, all RCTUs and BCUs 
Program Type:
Station
Initialized Default:
Does not assign “hunt-to” ports to any port
Program 22 Overview
This program assigns computer and Data Interface Unit (DIU) station hunt ports for data calls. If a 
RPCI/PDIU station (printer, modem, etc.) is busy, data station hunting allows the data call to hunt 
to an alternate RPCI/PDIU station assigned in this program. If the hunted RPCI/PDIU station is 
busy, the system will ring the next “hunt-to” station, and so on. If all RPCI/PDIU stations in the 
“hunt-to” sequence are busy, then the data caller will receive a busy tone. Toshiba recommends 
that all PDIU-DS station ports grouped in a modem pooling or printer pooling/server configuration 
be placed into a hunt-sequence arrangement with Program 22. 
Notes
Program 22 applies to RCPI-DI, PDIU-DI and PDIU-DS data calls, not telephone station 
voice calls. If programming an RCPI-DI or PDIU-DI station, use the associated DKT logical 
port number; the PDIU-DS is programmed using its own unique port number.
When a PDIU-DS is connected to a modem(s) assigned to the system modem pool in Program 
21, modem hunting is automatic when the user presses the 
'DWD&DOO
 button to transfer a line 
call to a modem. However, if the user dials the modem's PDIU-DS's station number, modem 
hunting follows the hunt sequence specified in Program 22.
✱  ✱  ✱ ✱  6SNU   +ROG  6SNU
+ROG  6SNU   +ROG  6SNU   +ROG
Processor Type
Port Range
Processor Type
Port Range
DK14
000~009
B1CU
000~055
DK40i
000~027
B2CAU/BU
000~111
RCTUA
000~031
B3CAU/BU
000~191
RCTUBA/BB
000~079
B5CAU/BU
000~335
RCTUC/D
000~239
RCTUE/F
000~335
Hunt From 
Port
Hunt To 
Port
Hunt From 
Port
Hunt To 
Port
Hunt From 
Port
Hunt To
Port
Hunt From 
Port
Hunt To 
Port
SELECT = Port Number (see legend below)
Enter the RPCI/DIU digital port number of the “hunt-from” station.
Enter the port number(s) to which class of service must be assigned. 
To add a port range, enter XXX
✱XXX (low port ✱ high port).
HUNT TO = (see legend below)
Enter the “hunt-to” RPCI/DIU digital port number.
LED Button 01 deletes a digit from the “hunt-to” 
port.