Toshiba DK40I 用户手册

下载
页码 424
System & Station
Program *42-1 – Primary Timing Reference Assignments (Release 3.1 and earlier)
3-130
Strata DK Programming     5/00
Program *42-1 – Primary Timing Reference 
Assignments (Release 3.1 and earlier)
Initialized Default:
Primary = 1, Secondary = 2
Program *42 for DK424
 
– 
T1 Assignment Series (Part 2)
See 
Program *42-1 Overview (Release 3.1 and earlier)
Assign the Primary Timing Reference with this program.
Note
RDTU No. 1 is the RDTU PCB installed in the lowest slot number of all RDTU PCBs, 
RDTU No. 2 is the RDTU PCB installed in the next highest slot number of all RDTUs and 
so on.
Primary/Back-Up Assignments Example
Note
A second RBOC T1 span line can also be used as the secondary clock source.
DK Master (free run) Assignment Example
Program *42-2 Overview (Release 3.1 and earlier)
Assign the Secondary (Backup) Timing Reference with this program.
Note
To assign RDTUs as the Master Clock Reference (free run), leave Programs 
42-1 and 
42-2 blank. Press button/LED 01 to enter blanks.
✱ ✱  ✱ ✱  6SNU ✱   +ROG  6SNU
+ROG  6SNU   +ROG  6SNU   +ROG
Select
RDTU PCB Number
Primary
Secondary
SEL = 1 or 2
1 - Primary Source
2 - Secondary Source
RDTU PCB Number (1~8)
Enter the RDTU PCB number that is connected to the 
primary reference T1 (span line) clock source.
Press LED Button 01 (blank) if the DK T1 is the master 
(free run) clock source.
1863
RDTU in 
Slot 13
RDTU in 
Slot 25
T1 – Primary PCB
T1 – Secondary PCB
Central Office
RBOC CO lines
AT&T or MCI
Long Distance Lines
Span Line
(Primary clock source)
Span Line
(Secondary clock source)
DK
Program Data
   
4 2 - 1  1   > 
Program Data
   
4 2 - 2  2   > 
Slot 13
T1 – PCB
Other DK
or PBX, etc
Span Line
(DK424 clock source)
DK
Program Data = blank button (Button 01) 
for 
  
 4 2 - 1 and     4 2 - 2
1864