Toshiba DK40I 用户手册

下载
页码 424
Overview
How to Program a Strata DK System
1-10
Strata DK Programming    5/00
How to Program a Strata DK System
Fill out the record sheets that are provided, then enter this data using a 20-button LCD digital 
(DKT) or electronic (EKT) telephone. Strata DK enables you to enter data from an on-site or off-
site PC with Toshiba DKi Admin software. Toshiba highly recommends this easier method of 
programming.
DK14/DK40i: the programming telephone must be any 20-button LCD DKT (or EKT, DK40i 
only). The DKT must be connected to a Base KSU, PDKU, RDSU, QCDU, or KCDU digital port. 
An EKT must be connected to a PEKU port.
DK424 and DK424i: the programming telephone must be a 20-button LCD DKT or EKT 
connected to circuit 6 of a PDKU or PEKU installed in cabinet slot 11 and/or slot 12.
Note
Telephones connected to an RDSU or PESU cannot be used to program DK424 or 
DK424i.
Programming Section Layout
Each programming section within a chapter begins with the program’s number and title, followed 
by processor and program type, initialized default, program sequence, then record sheets. A 
program overview and additional program information are given after the record sheets 
(see 
).
Note
Some common program sections also include examples for your convenience.
Program 30 Overview
Program 30 enables or disables features for individual telephones at the station level. The following 
text describes Program 30 LEDs.
Privacy Override, LED 19
With Privacy Override enabled (LED 19 ON), a station can override calls and listen to a CO line 
conversation by pressing a common CO line button (not a [DN] button).  You can set a warning tone 
for Privacy Override (see Program 10-2).
SELECT = Station Logical Port Number(s)
Buttons/LEDs
Light LEDs for the port specified in the 
last step. All LEDs marked with an “X” 
in the table below should be lit.
2174
Feature
LED
20
19
18
17
16
15
14
13
12
11
10
09
08
07
06
05
Port
Processor Type: DK14/DK40/DK424
Program Type: System
Initialized Default: LEDs 01, 05 and 07 for all ports
Program 30
Station Class of Service
Program 30 Station Class of Service
System Programs
Number/Title
Program Sequence
Record Sheet
Program Overview
Additional Program
Information
Processor Type
Program Type
Gives the type of processor that is 
compatible with the given program.  
Be sure to read this information 
before attempting to use a program 
with your system application.
Type of function the program 
performs.  Can be: Initialization, 
Test System, Station, Toll 
Restriction or Least Cost Routing.
Default configuration set by 
Program 91-9 “System 
Initialization” when the system is 
first installed or re-initialized.
Additional details on the program 
features that were given on the 
system record sheet.
Keystrokes for entering data 
from system record sheets 
follow a pattern, consisting of a 
five-step process described and 
illustrated in “Program 
Sequence” on Page 1-13.
Provides a list of available 
features. The sheet is used to 
record the assignment of 
features or the operation of each 
program. Each sheet provides 
space to record data. This data 
will be referred to when 
programming the system.
Brief description of program 
function(s).
Initialized Default
Program 30 Station Class of Service
System Programs
Figure 1-1
System Record Sheet Sample