Toshiba DK40I 用户手册

下载
页码 424
Automatic Call Distribution
Program 03 – RSIU, RSSU, PIOU, PIOUS ACD/MIS Slot Assignments
6-2
Strata DK Programming     5/00
Program 03 – RSIU, RSSU, PIOU, PIOUS ACD/MIS Slot 
Assignments
Initialized Default:
n/a
Program 03 Overview
This program is for specifying RSIU, RSSU, PIOU, or PIOUS ACD/MIS Slot Assignments.
If MIS output is required for ACD, set Code 42 for the slot in which the RSSU, PIOU or PIOUS is 
installed, or Code 49 if RSIU is installed in slot 11 (that connects to the SMIS personal computer). 
If you use RSIU/RSIS or TSIU for MIS output, you must set the appropriate port for MIS 
operation/speed using Program 76.
✱  ✱  ✱ ✱  6SNU   +ROG  6SNU
+ROG 6SNU   +ROG  Power Off (5 sec.) then On
Enter 42 to assign the PIOU, PIOUS, or RSSU 
TTY Port as MIS port, or enter 49 to assign RSIU 
to slot 11 (see Program 76 if installing RSIU).
DK40i TSIU does not require an entry in Program 
03.
PIOU, PIOUS, or RSSU Slot Number (12~78)
...or RSIU Slot Number 11