Toshiba DK40I 用户手册
System & Station
Program 03 for DK40i – Flexible PCB Slot Assignments
3-4
Strata DK Programming 5/00
Program 03 for DK40i – Flexible PCB Slot Assignments
Processor Type:
DK40i
Program Type:
System
Initialized Default:
PCB codes of PCBs installed prior to running Program 91-1 or Program 91-9
Code 00 for empty slots (15~18), Base KSU has codes for PCBs
Code 00 for empty slots (15~18), Base KSU has codes for PCBs
✱ ✱ ✱ ✱ 6SNU +ROG 6SNU
+ROG Turn System Power Off (5 sec) then On
more codes
...or
SELECT = Slot Number (00, 11~18)
CARD = PCB Code (See Reference Table)
Run Program 91-2
Notes
●
For systems containing ISDN PCBs, immediately after running
Program 03, make sure to run Program *60 to identify all
station (NT/LT) and CO (TE) BRI circuits for each BRI circuit
installed. Program *60 causes station port and CO line shifting
on PCBs installed in higher slots that follow the BRI PCBs.
Program 03, make sure to run Program *60 to identify all
station (NT/LT) and CO (TE) BRI circuits for each BRI circuit
installed. Program *60 causes station port and CO line shifting
on PCBs installed in higher slots that follow the BRI PCBs.
●
Consult DK40i configuration section to check that the DK40i is
configured properly.
configured properly.
●
RPTU and RDTU can be installed in slot 15 or 17 only. If one of
these PCBs is installed in slot 17, then slot 18 must be left
vacant. If an RPTU or RDTU is installed in slot 15, then slots
16, 17, and 18 can be used for other PCBs.
these PCBs is installed in slot 17, then slot 18 must be left
vacant. If an RPTU or RDTU is installed in slot 15, then slots
16, 17, and 18 can be used for other PCBs.
●
RWIU must be installed in slot 15 to provide 16 handsets or slot
17 to provided eight handsets.
17 to provided eight handsets.
DK40i Base KSU
DK40i Expansion KSU
TMAU2
DKU
TBSU,
TCOU,
TDDU or
TBUU
KSTU2
TCIU2
Slot Number
00
11
12
13
14
PCB Code
91, 92 or
98
98
62 or
64
64
00, 11, 16,
or 77
or 77
00 or
31
31
00 or
81
81
PCB Type
Options
Station/BRI
Port Numbers
CO/DID/BRI
Line Numbers
Cabinet Label
04
05
06
07
Slot Number
15
16
17
18
PCB Code
PCB Type
Options
Station/BRI Port Numbers
CO/Tie/DID/BRI/T1
Line Numbers
PCB Code Reference Table
PCB Fixed Slot
Code
Ports/Type
Common Control
91
None
Common Control w K4RCU3
92
4 DTMF/ABR
Common Control w/K5RCU or
K5RCU2
K5RCU2
98
5 DTMF/ABR
PIOU/PIOUS/RSSU/PEPU
41
None
PEKU
21
8 EKT
PEKU with EOCU
22
8 EKT
PEKU with DSS
23
8 EKT
PEKU with EOCU, DSS
24
8 EKT
PESU
25
2 SLT/4 EKT
PESU with EOCU
26
KSTU2/RSTU2/Stratagy DK
31
4 SLT/8 SLT/8VM
TCOU/PCOU/RCOU/RGLU2
11
4/CO
RCOU + RCOS
17
8 Loop CO
Base Unit DKT CKTs, PDKU,
and RWIU
and RWIU
61
8 DKT
Base Unit DKT CKTs
& PDKU w/ DIU or SP-OCA
& PDKU w/ DIU or SP-OCA
62
8 DKT
Base Unit DKT CKTs and
PDKU with DSS (w/ or w/o
DIU or SP-OCA)
PDKU with DSS (w/ or w/o
DIU or SP-OCA)
64
8 DKT
KCDU
65
2/CO, 4 DKT
KCDU SP-OCA or DIU
66
2/CO, 4 DKT
RDSU (RSTS)
27
4 DKT/4 SLT
RDSU (RSTS) with DIU or
SP-OCA
SP-OCA
28
4 DKT/4 SLT
RDDU/TDDU
16
4 DID Lines
RDTU
71
T1 Lines 8 ch. (R4.3)
72
T1 Lines 12 ch. (R4.3)
REMU 13
4-Tie
Lines
RCIU2/RCIS/TCIU2
81
4 or 8 Caller ID
TBSU or RBSU
77
2 BRI S/T
TBUU or RBUU
75
BRI U interface (R4.3)
RBSU/RBSS
78
4 BRI S/T
RBUU/RBUS
76
2 BRI U ckts.
RPTU
83
12 PRI Lines (R4.3)
84
8 PRI Lines (R4.3)
TSIU
No Code Required
None
00
None