System & Station
Program *03 for DK424 – Cabinet Type Identification
3-12
Strata DK Programming 5/00
Program *03 for DK424 – Cabinet Type Identification
Processor Type:
RCTUE/F or B5CAU/B5CBU
Program Type:
System
Initialized Default:
All cabinets = 1
Program *03 - Overview
You must run this program when using the DK424 or DK280 RCTUE/F, or DK424i B5CAU/BU.
It identifies which type of cabinets are installed (DK424i, DK424 or DK280).
It identifies which type of cabinets are installed (DK424i, DK424 or DK280).
The RCTUE/F processor can be installed in a DK424 or DK280 base cabinet. The expansion
cabinets can be any combination of DK424 and DK280 - except the seventh expansion cabinet
must be a DK424.
cabinets can be any combination of DK424 and DK280 - except the seventh expansion cabinet
must be a DK424.
The DK280 expansion cabinet can only support six universal PCB slots in any possible
configuration.
configuration.
The DK424 expansion cabinet supports eight universal PCB slots only if the RCTUE/F is installed
in a DK424 base cabinet and the MBJU jumper is removed from the DK424 base cabinet
backplane. MBJU does not apply with DK424i cabinets.
in a DK424 base cabinet and the MBJU jumper is removed from the DK424 base cabinet
backplane. MBJU does not apply with DK424i cabinets.
Important!
This programs exists on DK424i B5CAU/BU processors. It must always be set to
Cabinet Type “1” allowing 10 slots for each DK424i Expansion Cabinet. DK280
and DK424 Expansion Cabinets cannot be used with DK424i processors.
Cabinet Type “1” allowing 10 slots for each DK424i Expansion Cabinet. DK280
and DK424 Expansion Cabinets cannot be used with DK424i processors.
✱ ✱ ✱ ✱ 6SNU ✱ +ROG 6SNU
+ROG 6SNU +ROG 6SNU +ROG
SELECT =
(Cabinet No. 1~7)
Cabinet Type
(1 or 2)
1 (Base)
2 (1st Expansion)
3 (2nd Expansion)
4 (3rd Expansion)
5 (4th Expansion)
6 (5th Expansion)
7 (6th Expansion)
1 only
SELECT = Cabinet No. (1~7)
CABINET = 1 or 2 (type)
Type 1 (DK424 or DK424i)
Type 2 (DK280)
Type 1 (DK424 or DK424i)
Type 2 (DK280)
Turn System Power Off (5 sec) then On.
or...
Run Program 91-2
Expansion Cabinet Universal PCB Slot Availability
Case 1
RCTUE/F in DK424 Base Cabinet with MBJU removed
Note
MBJU is not used with DK424i cabinets.
Case 2
RCTUE/F in DK280 Base Cabinet
RCTUE/F in DK280 Base Cabinet
Expansion Cabinet (max 6)
Universal PCB Slots
DK424
1~8 available
DK280
1~6 available
Expansion Cabinet (max 5)
Universal PCB Slots
DK424
1~6 available
DK280
1~6 available