System & Station
Program 10-1 – System Assignments, Part 1 of 3
Strata DK Programming     5/00
3-27
System & Station
Program 10-1 – System Assignments, Part 1 of 3
Processor Type:
DK14, DK40i, all RCTUs and BCUs 
Program Type:
System
Initialized Default:
LEDs 07, 08, 09, 16, 18, 19 and 20 are On
✱  ✱  ✱ ✱  6SNU   +ROG  6SNU 
+ROG  6SNU   +ROG  6SNU   +ROG
Button/
LED
X
LED On
LED Off
20
Two-CO Line Conference/Allowed
Not Allowed
Two-CO line Conference must be allowed for Tandem Line, DISA, 
CF-EXT, and DNIS external routing operation. Also See Program 
15, Code 5.
19
Conference/Allowed
Not Allowed
18
Ring Detect Time-Normal
Ring Detect Time-Short Rings
17
Station to Station Call Volume PAD (-
8db)
No Station to Station Call PAD
16
BRI Standard Initialization (2 TEIs)
None (TEI = 0)
15~13
Not Used
Not Used
12
ABR Cycles/10 times
15 times
11
ABR Redial time/30 sec.
1 min.
10
System Speed Dial Override, Toll 
Restriction
Restricted
09
Exclusive Hold/Allowed
Not Allowed
08
Alternate Point Answer
Transfer Privacy
07
Ring Transfer of CO Line Allowed
Not Allowed
If Ring Transfer is allowed, set Ring Transfer Recall time in Program 
37; if ring transfer is not allowed (LED 07 Off), the station recalls 
immediately if transfer is attempted.
06
CO Line Repeat Ringing
Standard Ring
Standard ring pattern is 1 sec. on, 3 sec. off.
05
Incoming Call Abandon 8 sec.
6 sec.
04
CO Line DTMF Signal Time 160 msec.
80 msec.
LED 04 DTMF Signal Time applies to manual and speed dial tones 
sent out of the system via CO lines. This applies when dialing from 
any Toshiba telephone, including the 2000-series Digital Telephone. 
LED 04 does not apply to Call Forward or Voice Mail ID DTMF tones 
sent to voice mail ports. (See Program 10-2, LED 06, for tones sent 
to Voice Mail ports.)
03
Dial Pulse Make Ratio 33%
40%
02
0.45 or 1.5 sec. per Program 42-0
CO Line Re-seize guard time 0.45
CO line guard time is the time interval the system requires to release 
a CO line and reseize it. If LED 02 is off, all lines are set with 0.45 
second guard time; if LED is on, guard time is 0.45 or 1.5 seconds 
per Program 42-0.
01
Tone First (from SLTs, DKTs and EKTs)
Voice First (from SLTs, DKTs and EKTs)
This applies to [PDNs] not [PhDNs]; [PhDNs] are always tone first.
SELECT = 1
Light the LED Buttons that are marked with an X in 
the table below.