PC DIU/DIU Modem Pool Connection to Strata DK Modem
––––––––––––––––––––––––––––––––––––––––––––––
138
DKAdmin/DKBackup
To Make Connection
1. Select Customer from the Dial DK Option.
2. Call attendant at customer Strata DK from remote digital telephone (voice call using 
telephone handset).
3. From the remote digital telephone, press the 
Modem
 button to reserve the remote modem. 
The 
Modem
 button LED flashes.
4. When attendant answers, request to be transferred to the IMDU or RMDS (attendant must 
press 
Conf + # 1 9
) and ask attendant to hang up.
5. When you hear IMDU or RMDS modem tone, press the 
Data
 button on the remote digital 
telephone and then press 
F5
 (voice/modem) on the DKAdmin/DKBackup PC keyboard. 
The call is picked up by to the RSTU remote modem, disconnecting the voice path, and 
establishing the data path between the Strata DK modem, the PDIU-DS modem and the 
remote digital telephone PDIU/RPCI. The 
Data
 and 
Modem
 button LEDs are red steady.
6. After the IMDU or RMDS and remote modem communicate (handshake), proceed with 
DKAdmin/DKBackup.
7. After the DKAdmin/DKBackup session is complete, go to the File Menu and press 
h