Sony KP 61S75 用户手册
![Sony](https://files.manualsbrain.com/attachments/7e61ba04cadfce70cb41a1a70ef1d62a30f0a5fe/common/fit/150/50/682a2570dc00831b079177f57c62a2915dd3423eb752334060fbcf750d89/brand_logo.png)
– 35 –
KP-43T75/48S75/
53N77/53S75/61S75
RM-Y906
2-9. A BOARD AND G BOARD REMOVAL
2-11. HIGH-VOLTAGE CABLE INSTALLATION
AND REMOVAL
7 Two screws
(+BVTP 3x12)
(+BVTP 3x12)
4 Eight screws
(+BVTP 3x12)
(+BVTP 3x12)
6 G board
9 A board
3 Terminal board
8 Claw
5 Claws
Main bracket
1 Two screws
(Screws (4x20), tapping)
(Screws (4x20), tapping)
2 Seven screws
(+BVTP 3x12)
(+BVTP 3x12)
2-10.
PICTURE TUBE REMOVAL
4 Four screws
(Screw (4x20), tapping)
(Screw (4x20), tapping)
!º Four screws
(+BVTP 4x12)
(+BVTP 4x12)
!¡ Picture tube
Picture tube
8 Deflection yoke
9 Tension
spring*
spring*
2 Four screws
(Screw (4x20), tapping)
(Screw (4x20), tapping)
3
1 Four screws
(Screw (4x20), tapping)
(Screw (4x20), tapping)
7 Neck assy
6 CR board
5 Lens
Lens
* 53S75/61S75
Serial No. 9,500,001 and higher
Serial No. 9,500,001 and higher
CAUTION: Removing the arrow-marked
screws is strictly prohibited.
If removed, it may cause liquid spill.
If removed, it may cause liquid spill.
(1) Removal
1 Rubber cap
2 HV cable
turn 90
turn 90
°
1 HV cable
Gutter
Hook
(2) Installation