Dual View Series Service and Installation Manual
3
Delfield
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
Location
These units are intended for indoor use only. Be sure the 
location chosen has a floor strong enough to support 1000 
pounds of the cabinet and contents. Reinforce the floor as 
necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good 
air circulation inside and out.
Inside cabinet: Do not pack refrigerator so full that air 
cannot circulate.
Outside cabinet: Be sure that the unit has access to ample 
air. Avoid hot corners and locations near stoves and ovens.
Leveling
A level cabinet looks better and will perform better because:
  1. The drain pan will drain properly.
  2. The doors will line up with the frames properly.
  3. The cabinet will not be subject to undue strain.
To meet NSF standards, this unit must be sealed to the 
floor.
Installation of glass shelves
  1.  Remove stainless steel shelf bracket assemblies by 
sliding key slots over shoulder bolts on inside edges of 
posts.
  2. Plug light cords into receptacles.
  3. Place 0.25” safety glass shelves on brackets.
Installation of dry section front & side glass
  1. Remove (2) acorn nuts on bottom side of shelf.
 2. Remove top of stainless steel shelf by lifting shelf off 
subtop.
  3.  Place 0.25” thick side glass pieces into bottom channel 
and lower rear of stainless steel shelf.
  4.  Place 0.25” thick front glass piece into bottom channel 
and lower front of stainless steel shelf over top edge of 
glass.
  5.  Replace acorn nuts on bottom side of shelf.
Plumbing
Self-contained models are standard with a condensate 
evaporator. If the evaporator fails, the unit’s drain must have 
an outlet to an appropriate drainage area or container.
Moisture collecting from improper drainage 
can create a slippery surface on the floor 
and a hazard to employees. It is the owner’s 
responsibility to provide a container or outlet for 
drainage.
Electrical connection
Refer to the wattage data on page 2, the serial tag and your 
local code to be sure the unit is connected to the proper 
power source. A protected circuit of the correct voltage 
and amperage must run for connection of the line cord, or 
permanent connection to the unit.
Self-contained units have an ON/OFF switch located in the base 
of the unit. Simply turn the switch to ON to begin operation. 
The power switch must be turned OFF  and 
the unit disconnected from the power source 
whenever performing service or maintenance 
functions.
CAUTION
On self-contained models, after turning the ON/OFF switch 
to ON, the unit’s compressor will begin operating. Delfield 
display cases are designed to maintain an operation 
temperature of 36°F to 40°F at ambient room temperature of 
75°F and relative humidity of 55%.
Do not load the storage area in a way that restricts the air 
flow. Overloading will result in a loss of temperature.
Continuous opening and closing of the doors will hamper 
the units ability to maintain operational temperature.
Installation
Operation Information
Shelves
Front
Sides
(Top)
34.0” x 15.84”
(Center)
34.0” x 17.24”
(Bottom)
32.50” x 15.43”
24.95” x 35.0”
Two Each Required:
24.57” tall;
19.38” at bottom
15.04” at top
*** All glass shelving is .25” thick safety glass.***
Display Case Glass Replacement
Delfield professionally packages the glass in the crate 
to minimize the risk of freight damage. However, during 
shipment glass damage can happen and breakage is not 
covered under warranty. If your Delfield unit arrives with 
broken glass in the top dry section, we recommend that you 
purchase replacement glass locally. The table to the right lists 
replacement sizes for the dry top section only.
Please call your Delfield service or sales representative if you 
have any questions on glass replacement.