2–Pump 12-Station Controllers 
Chapter 3:  Installation 
27 
   PUMP SETTINGS?
       NO/YES 
 
     PUMP MODE?
       NO/YES 
 
   SET PUMP MODE?
  Y=SINGLE  N=DUAL 
 
Pump Settings Menu 
The Pump Settings menu lets you set all pump parameters. These include: 
•  Pump Mode 
•  Blowback 
•  Delay Time 
Setting the Pump Mode 
The first setting to be configured is the Pump mode. This function tells the controller how 
many pumps are connected to the system and how the pumps are to be controlled. 
You can select two pump modes: Single Pump mode and Dual Pump mode. In Single Pump 
mode (default), one (1) pump is used to convey material to all 12 stations. In Dual Pump 
mode, two (2) pumps are used simultaneously, resulting in a more efficient conveying 
process. 
From the main operating display (OFFLINE): 
1.  Press the MENU key repeatedly until the screen displays the following: 
 
 
 
 
 
 
 
To enter the Pump Settings menu: 
1.  Press the YES key. 
2.  Press the NO or MENU key repeatedly until the screen displays the following: 
 
 
 
 
 
 
 
 
To enter the Pump Mode setting menu: 
1.  Press the YES key. 
The screen displays the following: