• Tracking (RGB or Component sources): Tracking determines the frequency of the 
pixel sampling clock, indicated by the number of incoming pixels per line, so that all 
pixels generated by a particular source are sampled. 
Steady flickering or several soft vertical stripes or bands across the entire image 
indicates poor pixel tracking. Proper pixel tracking helps ensure that the image quality 
is consistent across the screen, that aspect ratio is maintained and that pixel phase 
(see above) can be optimized. 
• Sync Level (Component sources only): Select Sync Level to adjust the voltage level 
of the LS-1 Sync signal detection circuitry.
Sync Level adjustment is occasionally necessary when a DVD player or HDTV source 
signal drops “below black” (for example, during scenes with explosions or when 
subtitles are present) and causes the projector to temporarily lose sync. If the Sync 
Level f
rom the source is persistently too low, the projector won’t sync with the source 
at all. 
The range is from 50 to 256 millivolts (mV) inclusive. The default setting is 240 mV and 
should rarely require adjustment.