用户手册目录1 Overview151.1 MICROMASTER 411 / COMBIMASTER 411161.2 Design Features172 Installation192.1 Installation after a Period of Storage212.2 Ambient operating conditions222.3 Mechanical Installation MICROMASTER 411232.3.1 Preparation232.3.2 Installation Procedure242.3.3 Layout of MICROMASTER 411252.3.4 Installation of Cable Glands272.3.5 Mounting the Inverter on a Siemens Motor292.3.6 Wall Mounting the Inverter292.4 Mechanical Installation COMBIMASTER 411302.4.1 COMBIMASTER 411 Installation Procedure302.4.2 COMBIMASTER 411 Dimensional Detail312.5 Electrical Installation332.5.1 General332.5.2 Line and Motor Connections342.5.3 Control Cable Connections372.5.4 Motor PTC Connections382.5.5 Avoiding Electro-Magnetic Interference393 Commissioning413.1 Block Diagram433.2 General Information443.3 Commissioning Procedure Overview453.3.1 Ramp Times Using Jumpers463.3.2 Control Circuit Jumpers473.3.3 Default setup493.3.4 Commissioning Overview with BOP or AOP493.3.4.1 Commissioning with the Basic Operator Panel (BOP)503.3.4.2 Commissioning with the Advanced Operator Panel (AOP)533.3.4.3 Quick commissioning (P0010=1)533.3.4.4 Reset to Factory default553.4 General operation563.4.1 Default Operation563.4.2 Operation using “Pot = Run” Jumper573.4.3 Non - Default Modes of Operation583.4.4 If the Motor does not start up593.4.5 If a fault occurs594 Using the MICROMASTER 411 / COMBIMASTER 411614.1 Frequency Setpoint624.2 Command Sources (P0700)634.3 OFF and Braking Functions634.3.1 OFF1634.3.2 OFF2644.3.3 OFF3644.3.4 DC braking644.3.5 Compound Braking644.4 Control Modes (P1300)654.5 Faults and warnings655 System Parameters675.1 Introduction to System Parameters685.1.1 Access Levels685.2 Parameter Structure695.3 Parameter List (short form)706 Troubleshooting796.1 Troubleshooting with the Inverter LED806.2 Troubleshooting with the Basic Operator Panel806.3 Faults and Alarms816.3.1 Fault messages816.3.2 Alarm Messages877 Specifications937.1 Technische Daten947.2 Case Size Rating Information957.3 Tightening Torque, Cable cross sections for Power Supply and Motor Terminals967.4 Tightening Torque for Fixing Screws967.5 Fuses and Circuit Breakers978 Options998.1 MICROMASTER 411/COMBIMASTER 411 User Options998.2 MICROMASTER 411/COMBIMASTER 411 Programming Options1008.3 Basic Operator Panel (BOP) / Advanced Operator Panel (AOP)1018.4 PROFIBUS Module1028.5 EM Brake Module1038.6 MICROMASTER 411 Operator Panel Mounting Kit1048.7 PC to Inverter Connection Kit1058.8 PC to AOP Connection Kit1068.9 Door Mounting Kit for Single Inverter control1078.10 Wall Mounting Kit for MICROMASTER 4111089 Electro-Magnetic Compatibility (EMC)1099.1 Electro-Magnetic Compatibility (EMC)1109.1.1 Self-Certification1109.1.2 Technical Construction File1109.1.3 Emc Type Test Certificate1109.1.4 EMC Directive Compliance with Harmonics Regulations1109.1.5 Environment Classes of EMC performance1119.1.6 EMC Compliance Tests1139.1.7 MICROMASTER 411 – EMC Compliance11310 Engineering Information11510.1 Current Limit and Overload Operation11610.1.1 Current Monitoring Accuracy11710.1.2 Fast Current Limit11810.1.3 Positive Temperature Coefficient Resistor Use11810.1.4 I2t Performance11910.1.5 Internal Overtemperature11910.1.6 Overvoltage and Trip Levels11910.2 Control and Operating Modes12010.2.1 Boost12010.2.2 Proportional and Integral Control (PI)12110.2.2.1 What is Closed Loop control?12110.2.2.2 Implementation on MICROMASTER 411/COMBIMASTER 41112110.2.2.3 Setting up the PI controller12210.2.2.4 PI Setpoint ramp times12310.2.2.5 PI Controller Proportional and Integral terms12410.2.3 Ziegler-Nichols method of Optimization12610.2.4 PI Output Limits12810.2.5 Further features12810.2.6 Energy Saving Mode12910.2.6.1 Energy Saving Mode 1 (P2390 - P2392)13010.2.6.2 Energy Saving Mode 2 (P2393 - P2398)13110.3 Braking13210.3.1 DC Braking13310.3.2 Vdc Max Controller13310.3.3 Compound Braking13410.4 Derating Factors13510.4.1 Derating with Temperature13510.4.2 Derating with Altitude13510.4.3 Derating with Switching Frequency13610.4.4 Derating for Inverter Orientation13610.5 Thermal Protection and Automatic De-rating13710.6 Operation from Unearthed Supplies13710.7 Lifetime of Inverters13710.8 Working with Binary Connectors (BiCo)13810.8.1 Introduction13810.8.2 How does BiCo work?13810.8.3 Using Control and Status Words with BiCo14010.8.4 BiCo Connections14110.9 Harmonic Currents14510.9.1 Harmonic currents with 1% mains impedance14510.10 Use of MM4 Input Chokes14610.10.1 Mains Supply Impedance14610.11 Power Losses14610.12 Shock and Vibration14710.12.1 Vibration Stress during Operation (Single Sine Sweep)14710.12.2 Stress during Operation (Half Sine Shock)14710.12.3 Vibration and Shock stress during Transport14710.13 PROFIBUS14810.13.1 Overview14810.13.2 Using the PROFIBUS14810.14 PROFIBUS Module14910.14.1 Features of PROFIBUS Module14910.15 Variant Independent Options15210.15.1 Basic Operating Panel (BOP)15210.15.2 Advanced Operating Panel (AOP)15210.15.3 PROFIBUS Module15310.15.4 PC to Inverter Connection Kit15310.15.5 BOP/AOP Door Mounting Kit for Single Inverter Control15310.15.6 EM Module153Appendices155A Applicable Standards155B List of Abbreviations156C MICROMASTER 411 / COMBIMASTER 411 Parts Identification157D Index158文件大小: 4.4 MB页数: 164Language: English打开用户手册