用户手册目录Introduction2Table of Contents31. Overview52. Names and functions52.1. Outline52.2. RJ45 connector pin layout62.3. Example of connection to an EtherNet/IP™ and Modbus® TCP62.4. LED indicator73. Parameters83.1. Communication parameters83.2. The details of the parameter setting123.2.1. Device name (c081-c096)123.2.2. Assigning IP addresses (c504, c505-c516)133.2.3. Network error detection (c100 - c103, c523)143.2.4. Command data (c001-c006), Monitor data (c021-c026)153.2.4.1. How to use Instance 102/152 and 105/155153.2.4.2. fa06 (Communication command1)163.2.4.3. fa23 (Communication command 2)173.2.4.4. fa07 (frequency reference from internal option)183.2.4.5. fa50 (Terminal output data from communication)183.2.4.6. fa51 (Analog output (FM) data from communication)183.2.4.7. fd01 (Inverter operating status 1)193.2.4.8. fd00 (Output frequency)193.2.4.9. fd03 (Output current)203.2.4.10. fe35, fe36, fe37 (Monitoring of the analog input VIA, VIB, VIC)203.2.4.11. fe14 (Cumulative run time)203.2.4.12. fe40 (Analog output (FM))203.2.4.13. fc91 (Alarm code)213.2.4.14. fd06 (Input TB Status)213.2.4.15. fd07 (Output TB Status)224. Objects234.1. Identity Object (0x01)244.2. Message Router Object (0x02)264.3. Assembly Object (0x04)274.4. Connection Manager Object (0x06)284.5. Motor Data Object (0x28)294.6. Control Supervisor Object (0x29)304.6.1. Run/Stop Event Matrix324.6.2. State of the drive324.6.3. Control Supervisor State Transition Diagram324.7. AC/DC Drive Object (0x2A)334.8. Parameter Objects (0x64)344.9. Parameter Objects (0x65)364.10. Port Object (0xF4)374.11. TCP/IP interface Object (0xF5)384.12. Ethernet link object (0xF6)415. Configuration of the assemblies455.1. List of Assembly Object Instance455.1.1. Instance 20: CIP basic speed control output465.1.2. Instance 70: CIP basic speed control input465.1.3. Instance 21: CIP extended speed control output475.1.4. Instance 71: CIP extended speed control input475.1.5. Instance 100: Native drive output485.1.6. Instance 150: Native drive input485.1.7. Instance 101: Native drive output505.1.8. Instance 151: Native drive input505.1.9. Instance 102: Native drive output525.1.10. Instance 152: Native drive input525.1.11. Instance 105: TOSHIBA specific output535.1.12. Instance 155: TOSHIBA specific input536. About EDS file557. Integration in RSLogix™557.1. Create a new project557.2. Add a EtherNet/IP scanner to the I/O configuration567.3. Configure the VF-MB1/S15 EtherNet/IP module587.4. Download the program to the PLC607.5. Edit the I/O scan data628. Modbus TCP server658.1. Modbus TCP frames658.2. Drive Modbus servers658.3. List of Modbus functions supported658.4. "03 (0x03) Read Holding Registers" function668.5. "06 (0x06) Write Single Register" function678.6. "16 (0x10) Write Multiple Registers" function688.7. "23 (0x17) Read/Write Multiple Registers" function698.8. "43 (0x2B) Read Device identification" function708.9. Parameter data729. IO Scanning service739.1. Presentation739.2. Periodic variables7310. Example of the setup with PL7™7410.1. Defining the hardware configuration7410.2. BOOTP configuration7510.3. Configuring Modbus messaging7610.4. Configuring periodic variables7711. Command & Setpoint selection (Local/Remote)7812. Unusual diagnosis8012.1. Option error8012.2. Disconnection error of network cable8013. WebServer8113.1. Access to the webserver8113.2. Web pages structure8213.3. Drive monitor (Main menu: Monitoring)8313.4. Drive parameters (Main menu: Monitoring)8413.5. Network parameters (Main menu: Network Setup)8613.6. Modbus scanner (Main menu: Network Setup)8613.7. EthIP scanner (Main menu: Network Setup)8713.8. Administration (Main menu: Network Setup)8813.9. TCP/IP statistics (Main menu: Diagnostics)89文件大小: 1.7 MB页数: 89Language: English打开用户手册
用户手册目录Introduction2Table of Contents31. Overview52. Names and functions52.1. Outline52.2. RJ45 connector pin layout62.3. Example of connection to an EtherNet/IP™ and Modbus® TCP62.4. LED indicator73. Parameters83.1. Communication parameters83.2. The details of the parameter setting123.2.1. Device name (c081-c096)123.2.2. Assigning IP addresses (c504, c505-c516)133.2.3. Network error detection (c100 - c103, c523)143.2.4. Command data (c001-c006), Monitor data (c021-c026)153.2.4.1. How to use Instance 102/152 and 105/155153.2.4.2. fa06 (Communication command1)163.2.4.3. fa23 (Communication command 2)173.2.4.4. fa07 (frequency reference from internal option)183.2.4.5. fa50 (Terminal output data from communication)183.2.4.6. fa51 (Analog output (FM) data from communication)183.2.4.7. fd01 (Inverter operating status 1)193.2.4.8. fd00 (Output frequency)193.2.4.9. fd03 (Output current)203.2.4.10. fe35, fe36, fe37 (Monitoring of the analog input VIA, VIB, VIC)203.2.4.11. fe14 (Cumulative run time)203.2.4.12. fe40 (Analog output (FM))203.2.4.13. fc91 (Alarm code)213.2.4.14. fd06 (Input TB Status)213.2.4.15. fd07 (Output TB Status)224. Objects234.1. Identity Object (0x01)244.2. Message Router Object (0x02)264.3. Assembly Object (0x04)274.4. Connection Manager Object (0x06)284.5. Motor Data Object (0x28)294.6. Control Supervisor Object (0x29)304.6.1. Run/Stop Event Matrix324.6.2. State of the drive324.6.3. Control Supervisor State Transition Diagram324.7. AC/DC Drive Object (0x2A)334.8. Parameter Objects (0x64)344.9. Parameter Objects (0x65)364.10. Port Object (0xF4)374.11. TCP/IP interface Object (0xF5)384.12. Ethernet link object (0xF6)415. Configuration of the assemblies455.1. List of Assembly Object Instance455.1.1. Instance 20: CIP basic speed control output465.1.2. Instance 70: CIP basic speed control input465.1.3. Instance 21: CIP extended speed control output475.1.4. Instance 71: CIP extended speed control input475.1.5. Instance 100: Native drive output485.1.6. Instance 150: Native drive input485.1.7. Instance 101: Native drive output505.1.8. Instance 151: Native drive input505.1.9. Instance 102: Native drive output525.1.10. Instance 152: Native drive input525.1.11. Instance 105: TOSHIBA specific output535.1.12. Instance 155: TOSHIBA specific input536. About EDS file557. Integration in RSLogix™557.1. Create a new project557.2. Add a EtherNet/IP scanner to the I/O configuration567.3. Configure the VF-MB1/S15 EtherNet/IP module587.4. Download the program to the PLC607.5. Edit the I/O scan data628. Modbus TCP server658.1. Modbus TCP frames658.2. Drive Modbus servers658.3. List of Modbus functions supported658.4. "03 (0x03) Read Holding Registers" function668.5. "06 (0x06) Write Single Register" function678.6. "16 (0x10) Write Multiple Registers" function688.7. "23 (0x17) Read/Write Multiple Registers" function698.8. "43 (0x2B) Read Device identification" function708.9. Parameter data729. IO Scanning service739.1. Presentation739.2. Periodic variables7310. Example of the setup with PL7™7410.1. Defining the hardware configuration7410.2. BOOTP configuration7510.3. Configuring Modbus messaging7610.4. Configuring periodic variables7711. Command & Setpoint selection (Local/Remote)7812. Unusual diagnosis8012.1. Option error8012.2. Disconnection error of network cable8013. WebServer8113.1. Access to the webserver8113.2. Web pages structure8213.3. Drive monitor (Main menu: Monitoring)8313.4. Drive parameters (Main menu: Monitoring)8413.5. Network parameters (Main menu: Network Setup)8613.6. Modbus scanner (Main menu: Network Setup)8613.7. EthIP scanner (Main menu: Network Setup)8713.8. Administration (Main menu: Network Setup)8813.9. TCP/IP statistics (Main menu: Diagnostics)89文件大小: 1.8 MB页数: 89Language: English打开用户手册