3M 78-8135-4385-3-A Benutzerhandbuch

Seite von 28
 
12
 
78-8135-4385-3-A
11.5  Using the 3M
 Stripping Tool 6365-ST, remove the 
buffer in small increments until 21–22 mm (approx. 
7/8") of buffer is left.
11.6  Using a lint-free cloth moistened with isopropyl 
alcohol, clean the bare fiber to remove any oils or 
acrylate coating debris.
11.7   Check the final strip lengths and adjust if necessary.
12.0  Connector Mounting
12.1  While connector is still in oven, mount fiber into 
connector inserting until buffer stops inside the 
connector. Be sure to insert fiber within the guide tube 
at the rear of the connector.
Note:  Removing the connector holder from the oven prior 
to fiber insertion will cause adhesive to thicken rapidly, 
greatly limiting the time to insert the fiber.
Cable jackets should be approximately 1mm from the rear 
of crimp area when buffer is correctly located.
IMPORTANT: Do not lift the connector while in the load 
adapter during the heating process. This will prevent 
adhesive from bonding to the load adapter. If adhesive 
does adhere itself to the inside of the load adapter, use 
the cleaning pin to remove adhesive prior to inserting 
next connector. Use alcohol with the pin, if needed.
Note: To ease fiber insertion, make sure fiber is kept very 
straight when mounting. If resistance is felt when within 
1/8” of buffer, you are stubbing and should back out a short 
distance and re-enter making sure that the fiber is kept 
straight at all times.