Pfaff 1183 Benutzerhandbuch

Seite von 42
Care and maintenance
34
Further parameters see manual of the respective drive
10
.05.02 
Parameter list for control unit MD-4-95-220-CE
P
arameter
Description
S
et
ting range
S
et value
1
Speed max.
50 - 9999
4
Speed for start backtackl
50 - 8000
1500
5
Speed for end backtack
50 - 8000
1500
40
Thread wiper
ON - OFF
ON
46
Rotating direction of the motor
CW - CCW
CW
47
Selected machine class
0 - 101
62
61
Cutting speed 1
50 - 500
220
81
Needle position 6 (start cutting signal 2)
0 - 360°
40°
84
Needle position 5 (end cutting signal 1)
0 - 360°
90°
85
Needle position 9 (start thread tension 
release/start thread catcher)
0 - 360°
120°
87
Tension release after thread lever position at t.d.c.
0 - 1500ms
20ms
179
Needle position 2 (take-up lever raised) 
0 - 359°
83°
181
Needle position 1 - needle lowered (192 = off)
0 - 255
250
210
Switch on angle for thread trapper
0 - 359°
20°
211
Switch off angle for thread trapper
0 - 359°
90°
236
Machine version
0 = 1183; 1 = 1181
0 - 20
0
Group
P
arameter
Description
User lever
S
et
ting range
S
et value P40 ED
S
et value P40 PD2
9
985
Switch on angle for thread trapper
B, C
0 -255
67
67
986
Switch off angle for thread trapper
B, C
0 -255
206
206
989
Thread trapper at beginning of seam
1 = yes, 0 = no
B, C
0 - 2
0
0