Panasonic AW-CB400L Benutzerhandbuch

Seite von 104
20 (E)
ENGLISH
Input connectors
DC 12V IN:
XLR, 4 pins
GND:
GND terminal
Output connectors
CONTROL OUT 
TO CONTROL PANEL:
D-SUB 29-pin
CONTROL OUT 
TO CAMERA 1 to 5:
RJ45, camera control RS-422 level
10Base-T straight cable (UTP category 5), max. 1000 meters
Input/output connectors
INCOM (top panel):
XLR, 4 pins
TALLY/INCOM:
D-SUB 15-pin
TALLY: Contact input (do not apply a voltage in excess of 5V)
INCOM: 4-wire system
Switch functions:
DATA SET, menu, camera control selection, DTL, scene file selection, gain selection,
BAR/CAM switching, white balance selection, AWC, ABC, call, lens iris
AUTO/MANU/LOCK switching, option switches (1 to 4)
Adjustment functions:
LCD contrast, INCOM level, lens iris, menu settings, R-GAIN, B-GAIN, pedestal, R-PED,
B-PED
Ambient operating temperature:
–10°C to +45°C
Storage temperature:
–20°C to +60°C
Ambient operating humidity:
30% to 90% (no condensation)
Dimensions (W
!
H
!
D):
100
!
85
!
266 mm
Weight:
1.4 kg
Finish:
Colour resembling Munsell 3.5 paint
Weight and Dimensions indicated above are approximate.
Specifications are subject to change without notice.
Supply voltage:
DC 12.0 V
Power consumption: 3.8 W
Specifications
1
indicates safety information.