Harrington Hoists MR2 Benutzerhandbuch

Seite von 64
 
13 
 
2.0     Specifications 
2.1.1 
Product Code for MR2 Trolley Alone: 
 
2.1.2 
Operating Conditions and Environment 
Temperature Range:  -4° to +104°F  (-20° to +40°C) 
Humidity:  85% or less (no condensation) 
Noise Level:  85 dB or less (A scale: measured 1 meter away from the electric chain 
hoist) 
 Enclosure Rating:  Trolley Meets IP55, Pendant Meets IP 65 
Supply Voltage:  Standard 208-230/460V-3-60, Optional 575V-3-60, Special Voltages 
Available 
Intermittent Duty Rating: 
Single Speed – 40% ED 240 starts per hour 
Dual Speed – 27/13% ED with 78/162 starts per hour 
Trolley Duty Rating:  ISO M4/5; ASME H4 
 
 
 
Table 2-1  Trolley Specifications
 
 
Capacity 
(Ton) 
Product Code 
Standard 
Beam Flange 
Range 
(in) 
Optional Beam 
Flange Range 
(in) 
Min. 
Allowable 
Radius 
for Curve 
(in) 
Motor
*** 
Approx. 
Net 
Weight 
(lbs) 
 
Output 
(Hp) 
Current Draw 
(amps) 
 
208V or 
230V 
460V 
S
in
g
le
 
S
p
eed
 
MR2010L/S-FG 
2.28 to 5.00 
5.01 to 6.02  OR 
6.03 to 12.00 
31.5* 
0.54 
3.0 
1.5 
68 
MR2020L/S-FG 
3.23 to 6.02 
6.03 to 7.02  OR 
7.03 to 12.00 
31.5** 
0.54 
3.0 
1.5 
84 
Du
a
S
p
eed
 
MR2010SD-FG 
2.28 to 5.00 
5.01 to 6.02  OR 
6.03 to 12.00 
31.5 
0.54 
3.0 
1.5 
75 
MR2020SD-FG 
3.23 to 6.02 
6.03 to 7.02  OR 
7.03 to 12.00 
31.5 
0.54 
3.0 
1.5 
93