Pride Mobility 1103 Ultra Benutzerhandbuch

Seite von 55
Jazzy 1103 Ultra
                            www.pridemobility.com
19
I I I .   Y O U R   P O W E R   C H A I R
Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batteries and the
motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage to the motors and
the electronics. If the circuit trips, allow your power chair to “rest” for approximately one minute. Next, push in the circuit
breaker button, turn on the controller, and continue normal operation. If the main circuit breaker continues to trip repeat-
edly, contact your authorized Pride Provider.
Motor Connectors: This is where the controller connects to the motors. The motor connectors are color-coded with red
and yellow labels. The label color on the motor connector corresponds with the label color on the power pod.
Battery Connector: This is where the controller connects to the batteries.
Power Seat Connector: This is where the power seat actuator is connected to the power pod.
Charger Inhibit Connector: The charger inhibit enables the onboard charger to disable the controller during charging.
See VII. “Operation.”
BATTERY CONNECTOR
MOTOR CONNECTOR
CHARGER INHIBIT
CONNECTOR
AMMETER
CHARGER  POWER
CORD RECEPTACLE
ONBOARD  BATTERY  CHARGER
CHARGER CIRCUIT FUSE (ATO)
Figure 7. Jazzy 1103 Ultra Electrical Components
MOTOR  CONNECTOR
POWER  POD
POWER SEAT CONNECTOR
CIRCUIT BREAKER