Bryan Boilers K-350-S150-GI Benutzerhandbuch

Seite von 4
WATER BOILER DIMENSIONS—inches (cm)
A
B
C
D
E*
F
G
H
I
J
K
L
BOILER
Length
Flue
Flue
Overall
Gas Train
Supply
Return
W i d t h
Min. Tube
Height
Height
Floor to
MODEL
Over
Location
Size
Length Connection Nozzle
Nozzle
Outside
Removal
Over
Over
Flow
Jacket
Jacket
Clearance
Barometric
Jacket
Nozzle
K-350-W
107
1
/
4
54
1
/
8
24
123
1
/
4
2
1
/
2
 NPT
4 FLG
4 FLG
48
1
/
4
32
97
1
/
2
70
1
/
2
73
1
/
2
(272.42)
(137.48)
(60.96)
(313.06)
(6.35)
(10.16)
(10.16)
(122.56)
(81.28)
(247.65)
(179.07)
(186.89)
K-400-W
117
59
24
133
2
1
/
2
 NPT
6 FLG
6 FLG
48
1
/
4
32
97
1
/
2
70
1
/
2
73
1
/
2
(297.13)
(149.86)
(60.96)
(337.82)
(6.35)
(15.24)
(15.24)
(122.56)
(81.28)
(247.65)
(179.07)
(186.89)
K-450-W
129
3
/
4
65
3
/
8
26
145
3
/
4
2 NPT
6 FLG
6 FLG
48
1
/
4
32
99
1
/
2
70
1
/
2
73
1
/
2
(329.57)
(166.05)
(66.04)
(370.21)
(5.08)
(15.24)
(15.24)
(122.56)
(81.28)
(252.73)
(179.07)
(186.89)
K-500-W
142
1
/
2
71
3
/
4
28
158
1
/
2
2 NPT
6 FLG
6 FLG
48
1
/
4
32
101
1
/
2
70
1
/
2
73
1
/
2
(361.95)
(182.25)
(71.12)
(402.59)
(5.08)
(15.24)
(15.24)
(122.56)
(81.28)
(257.81)
(179.07)
(186.89)
K-550-W
155
1
/
2
78
1
/
4
30
171
1
/
2
2
1
/
2
 NPT
6 FLG
6 FLG
48
1
/
4
32
103
1
/
2
70
1
/
2
73
1
/
2
(394.97)
(198.76)
(76.20)
(435.61)
(6.35)
(15.24)
(15.24)
(122.56)
(81.28)
(262.89)
(179.07)
(186.89)
K-600-W
165
83
30
181
2
1
/
2
 NPT
6 FLG
6 FLG
48
1
/
4
32
103
1
/
2
70
1
/
2
73
1
/
2
(419.10)
(210.82)
(76.20)
(459.74)
(6.35)
(15.24)
(15.24)
(122.56)
(81.28)
(262.89)
(179.07)
(186.89)
K-650-W
178
89
1
/
2
30
194
2
1
/
2
 NPT
6 FLG
6 FLG
48
1
/
4
32
103
1
/
2
70
1
/
2
73
1
/
2
(452.12)
(277.33)
(76.20)
(492.76)
(6.35)
(15.24)
(15.24)
(122.56)
(81.28)
(262.89)
(179.07)
(186.89)
Bryan K Series Steam & Hot Water Boilers
Form No. 4950
©2002 Bryan Steam LLC
Printed in USA
13-4428
Bryan Steam LLC — Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone:765-473-6651 • Internet:www.bryanboilers.com
Fax: 765-473-3074  • E-mail: bryanboilers@iquest.net
NOTE: * Gas train and control location dimensinos will vary depending on job specifications and conditions.
Dimensions and specifications are subject to change without notice. Consult factory for certified dimensions.
STEAM BOILER DIMENSIONS—inches (cm)
A
B
C
D
E*
F
G
H
I
J
K
L
BOILER
Length
Flue
Flue
Overall
Gas Train
Supply Nozzle
Feed
W i d t h
Min. Tube
Height
Height
Floor to
MODEL
Over
Location
Size
Length Connection
15#
150#
Connect.
Outside
Removal
Over
Over
Flow
Jacket
Jacket
Clearance Barometric
Jacket
Nozzle
K-350-S
107
1
/
4
54
1
/
8
20
123
1
/
4
2
1
/
2
 NPT
6FLG
4  FLG
2  NPT
54
32
106
3
/
4
83
3
/
4
88
1
/
4
(272.42)
(137.48)
(50.80) (313.06)
(6.35)
(15.24)
(10.16)
(5.08)
(137.16)
(81.28)
(271.15)
(212.71)
(224.16)
K-400-S
117
59
24
133
2
1
/
2
 NPT
8 FLG
6 FLG
2 NPT
54
32
110
3
/
4
83
3
/
4
88
1
/
4
(297.13)
(149.86)
(60.96) (337.82)
(6.35)
(20.32)
(15.24)
(5.08)
(137.16)
(81.28)
(281.31)
(212.71)
(224.16)
K-450-S
129
3
/
4
65
3
/
8
24
145
3
/
4
2 NPT
8 FLG
6 FLG
2 NPT
54
32
110
3
/
4
83
3
/
4
88
1
/
4
(329.57)
(166.05)
(60.96) (370.21)
(5.08)
(20.34)
(15.24)
(5.08)
(137.16)
(81.28)
(281.31)
(212.71)
(224.16)
K-500-S
142
1
/
2
71
3
/
4
24
158
1
/
2
2 NPT
8 FLG
6 FLG
2 NPT
54
32
110
3
/
4
83
3
/
4
88
1
/
4
(361.95)
(182.25)
(60.96) (402.59)
(5.08)
(20.32)
(15.24)
(5.08)
(137.16)
(81.28)
(281.31)
(212.71)
(224.16)
K-550-S
155
1
/
2
78
1
/
4
24
171
1
/
2
2
1
/
2
 NPT
10  FLG
6  FLG
2  NPT
54
32
110
3
/
4
83
3
/
4
88
1
/
4
(394.97)
(198.76)
(60.96) (435.61)
(6.35)
(25.40)
(15.24)
(5.08)
(137.16)
(81.28)
(281.31)
(212.71)
(224.16)
K-600-S
165
83
24
181
2
1
/
2
 NPT
10  FLG
6  FLG
2  NPT
54
32
110
3
/
4
83
3
/
4
88
1
/
4
(419.10)
(210.82)
(60.96) (459.74)
(6.35)
(25.40)
(15.24)
(5.08)
(137.16)
(81.28)
(281.31)
(212.71)
(224.16)
K-650-S
178
89
1
/
2
24
194
2
1
/
2
 NPT
10  FLG
6  FLG
2  NPT
54
32
110
3
/
4
83
3
/
4
88
1
/
4
(452.12)
(277.33)
(60.96) (492.76)
(6.35)
(25.40)
(15.24)
(5.08)
(137.16)
(81.28)
(281.31)
(212.71)
(224.16)