Panasonic J-HD1400P Benutzerhandbuch

Seite von 68
56
Time code/user bits 
(continued)
Time code when power is not supplied
Even if the power is not supplied, the time code generator
operates for many hours (about 1 year) by using the backup
feature. And the accuracy when power is not supplied is
about ±30 seconds a month.
<Notes>
z When the time code generator advances regardless of the
operation mode, the backup function is enabled.
Š When the TCG switch in the front panel is set to
“PRESET” and the menu No. 504 RUN MODE is set
to “FREE.”
Š When the TCG switch in the front panel is set to “EXT”
and the external time code input set in menu No. 507
EXT TC SEL is disconnected from the connector on
the rear panel.
z When the settings in menu No. 25 SYSTEM FERQ are
revised, the advanced data will be cleared.
Timecodes recorded by this product
*1 The internal TCG value is used when the signal cannot be detected from the TIME CODE IN connector input.
*2 The internal TCG value is used when the SLTC or SVITC cannot be detected on the input video signal.
*3 Nothing is recorded if the SVITC cannot be detected on the input video signal.
*4 When menu No. 503 TCG MODE is set to AUTO, the REGEN and PRESET selection of the TCG switch is disabled.
*5 When menu No. 154 AUTO BACK is set to “OFF”, scene-to-scene continuity will be a normal recording.
TCG switch
Menu
No. 507 EXT TC SEL
Selected video 
input signal
Recorded timecode
SBC area
VAUX area
INT (REGEN/
PRESET)
---
1394
Internal TCG value
(Refer to the following table.)
Timecode on IEEE1394 digital 
input (VAUX area)
HD SDI
SVITC on input video signal*
3
EXT
EXT_L
1394
Timecode on IEEE1394 digital 
input (SBC area)
Timecode on IEEE1394 digital 
input (VAUX area)
HD SDI
Timecode from TIME CODE IN 
connector input*
1
SVITC on input video signal*
3
SLTC
1394
Timecode on IEEE1394 digital 
input (SBC area)
Timecode on IEEE1394 digital 
input (VAUX area)
HD SDI
SLTC on input video signal*
2
SVITC on input video signal*
3
SVITC
1394
Timecode on IEEE1394 digital 
input (SBC area)
Timecode on IEEE1394 digital 
input (VAUX area)
HD SDI
SVITC on input video signal*
2
SVITC on input video signal*
3
TCG switch
Menu
Recorded timecode
No.503
TCG MODE
No.505
TCG REGEN
No.506
REGEN MODE
For continuous 
recording
For assemble editing
For frame-by-frame 
shooting*
5
For insert editing
(Time code selection)
TC
UB
TC
UB
TC
UB
REGEN
SW
TC&UB
---
REGEN
TC
REGEN
PRESET
REGEN
PRESET
REGEN
PRESET
UB
PRESET
REGEN
PRESET
REGEN
PRESET
REGEN
PRESET
---
PRESET
REGEN/
PRESET*
4
AUTO
TC&UB
AS&IN
PRESET
REGEN
REGEN
ASSEM
PRESET
INSRT
PRESET
REGEN
TC
AS&IN
REGEN
PRESET
REGEN
PRESET
ASSEM
PRESET
INSRT
PRESET
REGEN
UB
AS&IN
REGEN
ASSEM
REGEN
PRESET
INSRT
PRESET
REGEN