Panasonic AJ-HD150FE Benutzerhandbuch

Seite von 120
– 106 –
Table of AUTO OFF Error messages
Monitor display
Description
VTR operation
(Restart condition)
CAP ROTATE TOO
SLOW
CAP TENSION ERROR
DEW
DRUM ROTATE TOO
FAST
E-FF
DRUM ROTATE TOO
SLOW
If  the  capstan  motor  speed  is  abnormally  low,  the 
AUTO  OFF  lamp  lights,  and  the  message  display 
flashes.
STOP
(POWER OFF
ON)
If an abnormal tension at the supply side is detected 
in the capstan mode, the AUTO OFF lamp lights, and 
the message display flashes.
STOP
(POWER OFF
ON)
If  condensation  is  detected,  the  AUTO  OFF  lamp 
lights,  the  message  display  flashes,  and  the  VTR  is 
transferred  to  the  eject  mode.  After  the  tape  is 
ejected,  the  drum  rotates  in  order  to  eliminate  the 
condensation.
When  the  condensation  has  been  eliminated,  the 
AUTO OFF lamp and message display go off, and the 
VTR can be used.
<Notes>
 1)
 2)
EJECT
(Normal operation
resumed after
condensation is
eliminated)
If  the  cylinder  motor  speed  is  abnormally  high,  the 
AUTO  OFF  lamp  lights,  and  the  message  display 
flashes.
STOP
(POWER OFF
ON)
If  the  tape  start  and  tape  end  are  detected  simulta-
neously either during or after loading, the AUTO OFF 
lamp lights, and the message display flashes.
STOP
(POWER OFF
ON)
If condensation is detected in the eject mode, the 
drum starts rotating as soon as it is detected.
If condensation is detected when the cassette has 
been  inserted,  the  drum  rotation  is  stopped,  and 
after the tape is ejected, the drum starts rotating.
If  the  cylinder  motor  speed  is  abnormally  low,  the 
AUTO  OFF  lamp  lights,  and  the  message  display 
flashes.
STOP
(POWER OFF
ON)
FRONT LOAD MOTOR
If  the  cassette  does  not  move  up  even  when  6 
seconds have elapsed since the VTR was transferred 
to the eject mode, the AUTO OFF lamp lights, and the 
message display flashes.
<Note>
If  the  cassette  does  not  move  down  inside  the 
machine  even  when  6  seconds  have  elapsed  since 
the  cassette  was  inserted,  the  VTR  is  transferred  to 
the eject mode.
STOP
(POWER OFF
ON)
LOADING MOTOR
When the unloading operation is not completed within 
6  seconds,  the  AUTO  OFF  lamp  lights,  and  the 
message display flashes.
<Note>
When the loading operation is not completed within 6 
seconds,  the  VTR  is  transferred  to  the  eject  (unload-
ing) mode.
STOP
(POWER OFF
ON)
FRONT LOAD ERROR
The AUTO OFF lamp lights and the message display 
flashes  when  the  take-up  reel  has  been  rotating  idly 
for  a  fixed  period  of  time  while  the  start/end 
processing  operation  during  loading  (half  position)  is 
being performed.
STOP
(POWER OFF
ON)
Counter display
CAP ROTA TOO
SLOW
CAP TENSION ERROR
DEW
DRUM ROTA TOO
FAST
E-FF
DRUM ROTA TOO
SLOW
FRONT LOAD MOTOR
LOADING MOTOR
FRONT LOAD ERROR