Panasonic AJ-HD150FE Benutzerhandbuch

Seite von 120
– 76 –
Setup menus
USER menu
<INTERFACE>
Item
Setting
No.
Superimposed
No.
Superimposed
Description
display
display
200
PARA RUN
0000
DIS
0001
ENA
201
9P SEL
0000
OFF
0001
ON
202
ID SEL
0000
OTHER
0001
DVCPRO
0002
ORIG
203
50P SEL
0000
OFF
0001
            ON
204
RS232C SEL
0000
OFF
0001
ON
205
BAUD RATE
0000
300
0001
600
0002
1200
0003
2400
0004
4800
0005
9600
206
DATA
0000
7
LENGTH
0001
8
207
STOP BIT
0000
1
0001
2
208
PARITY
0000
NON
0001
ODD
0002
EVEN
209
RETURN
0000
OFF
ACK
0001
ON
210
50P STBY
 0000
    OFF/ON
CMD
0001
ON
The underline on the setting item denotes the initial setting.
This selects whether two or more VTRs are to be operated in
synchronization.
0: No operation in synchronization
1: Operation in synchronization
<Note>
When operating two or more VTRs in synchronization, set all
the VTRs to 0001 (ENA). (See pages 9 and 17.)
This  selects  whether  the  9P  connector  functions  when  the
REMOTE/LOCAL switch has been set to REMOTE.
0: Do not function
1: Function
This  selects  the  ID  information  which  is  returned  to  the
controller.
0: 20 25H
1: The DVCPRO’s original ID (F0 33H) is returned.
2: The unit’s original ID (A0 50H) is returned.
<Note>
The 2(ORIG) setting should only be used when a Panasonic
controller (AJ-A900 etc, sold separately) is connected.
This selects whether the PARALLEL (50P) connector functions
when the REMOTE/LOCAL switch has been set to REMOTE.
0: Does not function
1: Functions
These  settings  are  for  selecting  whether  the  RS-232C
connector is to function when the REMOTE/LOCAL switch is
set to REMOTE.
0: Connector does not function.
1: Connector functions.
These settings are for selecting the RS-232C communication
speed (baud rate).
These  settings  are  for  selecting  the  RS-232C  data  length.
(Unit: bit)
These settings are for selecting the RS-232C stop bit length.
(Unit: bit)
These settings are for selecting the none, odd or even for the
RS-232C parity bit.
0: Parity bit is not used.
1: An odd number of bits is used for the parity system.
2: An even number of bits is used for the parity system.
These settings are for selecting whether the ACK code is to be
returned when a command is received from RS-232C.
0: ACK code is not returned.
1: ACK code is returned.
For  selecting  the  method  used  to  detect  the  STANDBY
COMMAND signal input at the PARALLEL (50P) connector.
0: Each time active signals are detected, the STANDBY ON or
STANDBY OFF mode is selected alternately.
1: When  active  signals  are  detected  in  the  STANDBY  OFF
mode,  the  unit  is  transferred  to  the  STANDBY  ON  mode.
Nothing happens if they are detected during an operation in
the STANDBY ON mode.