Before requesting service, use this chart and see if you can repair the trouble yourself. Small problems are often easily corrected, and this 
can save you from the trouble of sending your VCR off for repair.
Power
Playback
Recording
Timer Recording
Other Problems
Troubleshooting
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
The power will not come 
on.
● The AC power cord is disconnected.
● Connect the AC power cord.
● The Child Lock function is activated.
● Press and hold POWER 1 for more than 
10 seconds to release the Child Lock function. 
(
pg. 16) 
The clock works, but the 
VCR’s power will not come 
on.
● The VCR is in the timer recording standby mode 
with “AUTO TIMER” set to “OFF” (
pg. 15).
● Press TIMER to disengage the timer.
● The Child Lock function is activated.
● Press and hold POWER 1 for more than 
10 seconds to release the Child Lock function. 
(
pg. 16)
The Remote will not 
function.
● The batteries are discharged.
● Replace batteries.
● The VCR is in the timer recording standby mode. ● Press TIMER to disengage the timer.
● Remote control A/B code is wrong.
● Reset A/B code. (
pg. 17)
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
The tape is running but the 
picture will not appear.
● If the RF connection (
pg. 6) is used to view the 
picture, the channel on the TV is set incorrectly.
● Select channel 3 or 4 on the TV.
● If the AV or S-video connection (
pg. 6) is used 
to view the picture, the TV receiver is set to the 
wrong mode.
● Select the AV mode on the TV.
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Recording will not start.
● There is no cassette loaded.
● Insert a cassette on which the record safety tab is 
intact.
● The loaded cassette has had its record safety tab 
removed.
● Remove the cassette and cover the hole with 
adhesive tape, or load a cassette on which the 
record safety tab is intact.
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Timer recording will not 
work.
● The clock and/or the timer program have been set 
incorrectly.
● Set the clock and/or timer program correctly.
● The timer is not engaged.
● Press TIMER to engage the timer and make sure 
that # appears on the display panel.
● The VCR has not been set up properly.
● Re-perform the set-up procedures. Make sure you 
have compensated for guide channel and VCR or 
cable box channel number mismatches. (
pg. 12)
Timer programing will not 
work.
● Timer recording is in progress.
● Timer programing cannot be performed when 
timer recording is in progress. Wait until it finishes.
You moved, and now VCR 
Plus+ system does not 
work properly
● The receivable stations in the new area are 
received on different channels than those in the 
previous area.
● Re-perform the procedure in “Changing VCR 
Plus+
®
 Setting” (
pg. 12).
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
The channel cannot be 
changed.
● Recording is in progress.
● Press PAUSE (9) to pause the recording, change 
channels, then press PLAY (4) to resume 
recording.
Even though Auto or 
Semiauto Clock Set has 
been performed, the clock 
is incorrect.
● The clock setting data received from the host 
channel is incorrect.
● Select a different host channel during Semiauto 
Clock Set (
pg. 7), or perform Manual Clock Set 
(
pg. 8).