Error Messages
When  a  problem  has  occurred  in  the  unit,  one  of  the
following  messages  will  appear  on  the  front  panel’s
counter  display  and  superimposed  display  on  the
monitor.
With  the  superimposed  display,  the  error  number  is
indicated  in  the  part  where  the  counter  value  is
displayed.
When “T&S&M” has been selected as the setup menu
item No.006 setting, the error message appears in the
part  of  the  superimposed  display  where  the  mode  is
displayed.
Error No.
Error message and description
– – d – –
DEW
Condensation has formed.
The  unit  can  still  be  operated  if  “ON”  has  been
selected  as  the  setup  menu  item  No.152  (HUMID
OPE) setting.  The counter value and “– – d – –” appear
alternately on the front panel counter display.
E – 00
SERVO NOT LOCKED
This  appears  when  the  servo  lock  has  been
disengaged for 3 or more seconds during playback or
recording.
E – 01
LOW RF
This  appears  when  the  head  output  is  not  supplied
(due  to  head  clogging,  etc.)  for  1  or  more  seconds
during playback.
E – 02
HIGH ERROR RATE
This  appears  when  the  error  rate  has  deteriorated,
and  the  video  or  audio  playback  signals  have  been
corrected or interpolated.
E – 09
NO RF
This  appears  when  a  tape  blank  has  been  detected
for 1 or more seconds during playback.
A  state  in  which  all  of  the  following  conditions  are
satisfied is recognized as a blank.
O
No output from any of the heads.
O
Playback data cannot be read.
O
No CTL signal.
E – 10
FAN STOP
This appears when the fan motor has stopped.  
The  power  is  automatically  turned  off  when  5  or  so
minutes have elapsed since the motor stopped.
E – 29
FRONT LOAD MOTOR
This  appears  when  the  cassette  fails  to  rise  even
when  6  seconds  have  elapsed  after  the  unit  was
transferred to the eject mode.
E – 31
LOADING MOTOR
This appears when the unloading operation fails to be
completed within 6 seconds.
E – 51
FRONT LOAD ERROR
This  appears  when  the  take-up  reel  has  continued  to
rotate  without  engaging  with  the  tape  for  a  specific
period  of  time  during  the  start  or  end  processing
operation  performed  midway  through  loading  (half
position).
E – 52
W-UP REEL NOT ROTA
This appears when the take-up reel fails to take up the
tape  while  the  tape  is  traveling  in  a  state  where  its
total  tape  length  has  not  been  detected  after  the
cassette was inserted.
E – 53
WINDUP ERROR
This  appears  when  there  is  an  abnormal  difference
between the tape take-up amount on the take-up reel
and the amount of tape supplied from the supply reel
while  the  tape  is  traveling  after  the  total  tape  length
was detected.
E – 55
UNLOAD ERROR
This  appears  when  the  tape  has  not  been  taken  up
during unloading.
E – 57
S-FF/REW TIMEOVER
This  appears  when  the  tape  start  or  end  processing
operation fails to be completed.
E – 59
DRUM ROTA TOO SLOW
This appears when the rotational speed of the cylinder
motor is abnormally low.
E – 60
DRUM ROTA TOO FAST
This appears when the rotational speed of the cylinder
motor is abnormally high.
E – 61
CAP ROTA TOO SLOW
This appears when the rotational speed of the capstan
motor is abnormally low.
E – 64
S REEL TOO FAST
This appears when the rotational speed of the supply
reel motor is abnormally high.
E – 67
T REEL TOO FAST
This appears when the rotational speed of the take-up
reel motor is abnormally high.
E – 69
T REEL TORQUE ERR
This  appears  when  the  application  of  an  abnormal
torque has been detected at the take-up reel motor.
E – 6A
This error number appears on the front panel counter
display  when  a  communication  error  has  occurred
between  the  IF  and  FRONT  microcomputers.    The
superimposed  display  itself  is  cleared  from  the
monitor screen.
E – 6B
FRP ERROR
This  appears  when  an  error  has  occurred  in  the
microcomputer reference signal.
E – 70
S REEL TORQUE ERR
This  appears  when  the  application  of  an  abnormal
torque has been detected at the supply reel motor.
E – 71
CAP TENSION ERROR
This  appears  when  abnormal  supply  reel  tension  has
been detected in the capstan mode.
E – 72
REEL TENSION ERROR
This  appears  when  abnormal  supply  reel  tension  has
been detected in the reel mode.
E – 73
REEL DIR UNMATCH
This appears when the take-up reel motor is rotated in
the wrong direction.
E – bA
BATTERY
This appears when the input DC voltage has dropped
below the lower voltage limit (approx. 10.6 V).
Error No.
Error message and description