Toshiba EM1-31064JE Benutzerhandbuch

Seite von 96
16-1
16. ERROR MESSAGE TABLE
EM1-31064
16.  ERROR MESSAGE TABLE
16. ERROR MESSAGE TABLE
Take the following action if an error message appears on the commodity name display along with the
buzzer sounding.
 Programming Mode
Message
Cause
Solution
DATA ENTRY ERROR
MEMORY FULL
DUPLICATE PLU
PLU NOT FOUND
CHARACTER
OVERRUN
PRT FAILURE
DETECTED
LABEL OVERRUN
RESTORE THE PLUS
Error in key input.
No memory space to set PLU.
The PLU # being changed is
already registered.
The PLU # being called is not
registered.
Attempt is made to set more
than max.  allowed number of
characters.
Printer trouble.
Label overruns.
The capacity of RAM was
changed with the ingredient
data stored.
Press the   CLEAR   key, and re-
input the right data.
Press the   CLEAR   key, and
delete unnecessary PLUs.
Press the   CLEAR   key, and
check the PLU.
Press the   CLEAR   key, and set
the data to free PLU#.
Press the   CLEAR   key, and re-
input the right data.
1. Check that the media and print
head are set correctly.
2. If the label home position is
misaligned, press the   FEED
key.
Press the   FEED   key.
Press the   CLEAR   key and save
the ingredient data.  Then delete
the data from the memory of the
unit.  After that change the capacity
of RAM and load the data to the
unit.
WARNING!
If you cannot solve the problem with the following solution instruction, do not attempt
further troubleshooting by yourself.  Turn the power off, unplug the scale, then contact
TOSHIBA TEC Authorized Service representative for assistance.
Do not attempt to repair or adjust alone, because electrical equipment is dangerous