Finisar Brocade Fabric Watch Benutzerhandbuch

Seite von 41
3-4
Fabric Watch User’s Guide
Using Fabric Watch
3
Monitors ALPA devices of Loop ports (currently CRC error of 
ALPA device only). 
End-to-End
1 -   Monitors transmitting performance predefined by the 
SID-DID pair. Configurable with either telnet commands or 
Web Tools at run time.
2 -   Monitors receiving performance predefined by the SID-DID 
pair. Configurable with either telnet commands or Web Tools 
at run time.
3 -   Monitors CRC errors of prefedined SID-DID pair. 
Configurable with either telnet commands or Web Tools at run 
time.
The configuration information of the End-to-End class is lost when 
the switch is rebooted or fast booted.
Note:
The End-to-End class is only available if the optional 
Performance Monitoring license has been purchased and 
turned on.
Note:
The EE filter is preconfigured with either a telnet command 
or Web Tools at run time.
Filter
Monitors the filter counter for a given port. Provides the following 
types of information about the filter hit:
1 - Read command
2 - SCSI or IP traffic
3 - SCSI Read/Write
Note:
 The Filter class is only available if the optional 
Performance Monitoring license has been purchased and 
turned on.
Note:
The type of filter is predefined by configuring it with either 
a telnet command or Web Tools at run time.
In addition, each class is subdivided into areas, as listed in the following table.
Table 3-1
 Fabric Watch Classes and Areas                                                                  
Class
Area
Description
Fabric
Loss of E_Port
Monitors E_Port status.
Fabric reconfiguration
Monitors fabric configuration 
changes.
Segmentation changes
Monitors segmentation changes.
Domain ID changes
Monitors forcible DOMAIN ID 
changes.